background image

23!,IGHTING4OPANGA#ANYON"LVD#HATSWORTH#!

4OLL&REEss&AX

¥23!,IGHTINGs!LL2IGHTS2ESERVEDs3PECIlCATIONSARESUBJECTTOCHANGEWITHOUTNOTICE

WWWCOOPERLIGHTINGCOM

WWWRSALIGHTINGCOM

"742

2%6

#ONSTRUCTED OF EXTRUDED ALUMINUM CHANNEL WITH A CONTINUOUS

INSULATOR #ONTINUOUS ACCESS SLOT ALLOWS lXTURES TO BE

ATTACHEDATANYLOCATIONASCLOSETOGETHERORASFARAPARTAS

DESIRED)NSTALLSSEAMLESSLYINTODRYWALLCEILING

s!##/--/$!4%3$297!,,#%),).'3&2/-v4/

v4()#+

s#%),).'-5$$).'#/-0/5.$)3!00,)%$2)'(44/

4(%%$'%/&4(%/0%.).'

s#/-0!4)",%7)4(!,,02/&),%3%2)%3&)8452%3

"USWAY IS OFFERED IN THREE VOLTAGE TYPES AND IN ONE OR TWO

CIRCUITS 6OLTAGE CAN BE MIXED IN TWO CIRCUIT CONlGURATIONS

FOREXAMPLE4WOCIRCUITCHANNELWITH6OLTSONONECIRCUIT

AND6OLTSONTHESECONDCIRCUIT%ACHCIRCUITISRATEDFOR

6OLTSMAXIMUM4HEHOUSINGSERVESASACAPACITY

GROUND

!FULLSELECTIONOFPOWERFEEDSANDCONNECTORSAREAVAILABLE

s-ANUFACTUREDWITHSERIESALUMINUM

s#ANACCOMMODATEvvDRYWALL

s0ROVIDESSEAMLESSINSTALLATION

s62ATING

s#ONTINUOUS!CCESS3LOT

s)NTERNALLY0OLARIZED

s3OLID#OPPER#ONDUCTORS

s5PTO3UPPORT)NTERVALS

s$URABLE0OWDER#OAT&INISH

!MP"USWAY2ECESSED4RIMLESS-OUNTED

/NEOR4WO#IRCUIT666

!22

#ATALOG

4YPE

0ROJECT

u

u

u

u u

u

u

u

u

u

l

l

l l

l

n

n

n

n

n

    

6OLTS#IRCUIT

 

6OLTSs#IRCUIT

 

6OLTSs#IRCUIT

 

6OLTSs#IRCUIT

 

6OLTSs#IRCUIT

 

6OLTSs#IRCUIT

 

6OLTSs#IRCUIT

 

6OLTSs#IRCUIT

 

6OLTSs#IRCUIT

u

6OLTS

l

6OLTS

n

6OLTS

)TEM

"USWAY,ENGTH

#IRCUITS6OLTAGE

&INISH

 

!22 

!MP"USWAY3ECTION

FOR2ECESSED-OUNTING

 

3PECIFY,ENGTH

???????????????

FROMTOFEETINv

INCREMENTS

 

#IRCUIT6OLTS

 

7(

 7HITE

 

#IRCUIT6OLTS

 

"+

 "LACK

 

#IRCUIT6OLTS

 

)3

)NDUSTRIAL3ILVER

 

#IRCUIT6OLTS6OLTS

 

04

 #USTOM&INISH

 

#IRCUIT6OLTS6OLTS

 

#IRCUIT6OLTS6OLTS

 

#IRCUIT6OLTS6OLTS

 

#IRCUIT6OLTS6OLTS

 

#IRCUIT6OLTS6OLTS

/RDERING%XAMPLE!22)3

$ESCRIPTION

!MP"USWAY3ECTIONFOR2ECESSED-OUNTINGFOOTLENGTH#IRCUIT6OLTS6OLTS )NDUSTRIAL3ILVER&INISH

!22

#IRCUIT)NDICATOR

!CCOMMODATES

TODRYWALL

-UDDINGCOMPOUNDAPPLIED

RIGHTTOTHEEDGEOFTHEBUSWAY

"ACKINGWINGPROVIDES

SECUREMOUNTING

TODRYWALL

#IRCUIT)NDICATOR

4"AR

#EILING&LANGE

#EILING4ILE

#IRCUIT)NDICATOR

#IRCUIT)NDICATOR

530ATENT.UMBER

_____

_____

Содержание PROfile AR60R

Страница 1: ...DES SEAMLESS INSTALLATION s 6 2ATING s ONTINUOUS CCESS 3LOT s NTERNALLY 0OLARIZED s 3OLID OPPER ONDUCTORS s 5P TO 3UPPORT NTERVALS s URABLE 0OWDER OAT INISH MP USWAY 2ECESSED 4RIMLESS OUNTED NE OR 4WO IRCUIT 6 6 6 2 2 ATALOG 4YPE 0ROJECT u u u u u u u u u u l l l l l n n n n n 6OLTS IRCUIT 6OLTS s IRCUIT 6OLTS s IRCUIT 6OLTS s IRCUIT 6OLTS s IRCUIT 6OLTS s IRCUIT 6OLTS s IRCUIT 6OLTS s IRCUIT 6OLT...

Страница 2: ...H v v v NTERNAL IRCUIT NDICATOR XTERNAL IRCUIT NDICATOR 2 4 22 4 ONNECTOR 2ECESSED OUNT NTERNAL IRCUIT NDICATOR 2IGHT 2 4 2 4 ONNECTOR 2ECESSED OUNT NTERNAL IRCUIT NDICATOR EFT 2 4 22 4 ONNECTOR 2ECESSED OUNT XTERNAL IRCUIT NDICATOR 2IGHT 2 4 2 4 ONNECTOR 2ECESSED OUNT XTERNAL IRCUIT NDICATOR EFT IRCUIT IRCUIT 7 7HITE LACK 3 NDUSTRIAL 3ILVER 04 USTOM INISH v v v NTERNAL 2IGHT XTERNAL 2IGHT XTERNAL...

Страница 3: ...ICATOR IRCUIT IRCUIT 7 7HITE LACK 3 NDUSTRIAL 3ILVER 04 USTOM INISH 0 7 2 3 2 2 33 42 33 5 4 537 9 TEM IRCUITS INISH 2 0 2 ND EED 4OP FOR 2ECESSED OUNTING IRCUIT IRCUIT 7 7HITE LACK 3 NDUSTRIAL 3ILVER 04 USTOM INISH 2 2 ENTER EED 4OP FOR 2ECESSED OUNTING IRCUIT IRCUIT 7 7HITE LACK 3 NDUSTRIAL 3ILVER 04 USTOM INISH 2 2 ND EED ND FOR 2ECESSED OUNTING IRCUIT IRCUIT 7 7HITE LACK 3 NDUSTRIAL 3ILVER 04 ...

Страница 4: ...ORT ABOVE BUSWAY 7 7HITE LACK 3 NDUSTRIAL 3ILVER 04 USTOM INISH 2 ANGER OLT TTACHMENT ON ELECTRICAL DEVICE FOR SUSPENSION OF ACCESSORIES FROM THE USWAY 7 7HITE LACK 3 NDUSTRIAL 3ILVER 04 USTOM INISH TEM 6OLTAGE INISH 2 2 0RONG 2ECEPTACLE OX 6 ONLY 2 2 4 4WIST OCK 2ECEPTACLE OX MP FUSED RECEPTACLE IN OX WITH USWAY ADAPTER 7 7HITE LACK 3 NDUSTRIAL 3ILVER 04 USTOM INISH 2 IXTURE 0ENDANT DAPTER USWAY ...

Отзывы: