Instruction Leaflet
RS
stock no. 312-353, 312-369
Issued April 1997
7798
Programmable
Counter/Timer
A range of solid-state counter/timers for industrial control applications
in manufacturing, packaging and materials handling, also process
timing and monitoring functions. Made in Japan.
●
Easy to programme
●
Four timer or counter modes
●
Wide range of supply voltages
●
Choice of a.c. or d.c. operation
●
6-digit LCD display
●
Non-significant zeros suppressed
●
Up or down counting to 10
6
operations
●
Timing from 0.01s to 10
5
hrs
●
4 output, 3 input modes
●
Manual and remote reset facilities
●
Memory back-up via internal battery
●
Time integrating facility
●
Standard DIN 48 case
●
11-pin relay base
●
DIN-rail, surface mounting or panel mounting hardware available
●
UL and CSA approved
Dimensions
RS
stock no. 312-353 Voltage range: 24 to 240V a.c.
Omron reference: H8CA - SAL
RS
stock no. 312-369 Voltage range: 12 to 120V d.c.
Omron reference: H8CA - SDHS
Accessories
Connections
1.
ME* - enables selection timer/counter mode
2.
Supply
3.
Input common
4.
TC* - inhibits timer operation during supply failure
5.
CP2 - see timer/counter input modes
6.
CP1 - see timer/counter inputs modes
7.
R - resets the timer/counter and turns the output off
8.
See diagram (below)
9.
See diagram (below)
10. Supply
11. See diagram (below)
Counter
Operating mode N
The display increments when an input is received. On reaching the set
value the output is turned on and the display is held. This continues until
a reset is applied.
Operating mode F
Operation is for mode N except that when the set value is reached the
display continues to increment.
Operating mode C
The display increments until the set value is reached. At this point the
output is turned on for a period of approx. 0.5sec., the counter is reset,
and begins to count again.
Note:
In this mode the unit should not be used in such a way that the
set value is reached during the timed output.
Operation is as for mode C except that the count is held at zero during
the timed output period.
Operating mode R
Input mode A
CP1 count input: counter increments or decrements
when input is closed.
CP2 count direction: CP2 OFF gives count up: CP2 ON
gives count down.
Input mode B
CP1 count input: counter increments when input
0.5s
0.5s
6
5
4
3
2
1
11
10
9
8
7
8
9
11
8
9
11
7.8
3
4.5
35.4
31 max
50 max
70
max
11.M3.5 x 7.5
¯ 4.5
9
3
4
5
6
7
8
2
1
11
10
48
COUNTER/TIMER
0
RST
WRITE
63.7
0.7
13.6
44.8
78
86
6
8
Warning:
This product contains a 3V
lithium polycarbon -
monofluoride type battery which
must not be charged, cut open,
disposed of in a fire, or
subjected to direct mechanical
shock.
RS
stock no. 342-922
Panel mounting adaptor
Omron reference:Y92F-30
RS
stock no. 342-922
DIN rail/surface-mounting screw terminal with 11-pin
socket base.
Omron reference:Y92F-30
R
CP1
T.C.
M.E.
a.c. type
RS
stock no. 312-353
set
Figure 1
display
output
count
set
Figure 2
display
output
count
d.c. type
RS
stock no. 312-369
* Link ME (1-3) is only required during
installation
Link TC (4-3) is an option in the timer
mode only. Do not link in counter mode.
CP2
set
Figure 3
display
output
count
set
Figure 4
display
output
count