Tuning by Gain Setting
8-39
CSD7 Servo Drive (EtherCAT)
Initial Torque Bias
It is the function to prevent downturn by the gravity of vertical load
during initial operation.
Downturn of Load by Gravity and Initial Torque Bias
If you enter Servo-ON signal to operate motor in the condition that
load is vertical as shown in the figure, downturn of load by gravity
can occur.
In addition, in case of Servo-On or Servo-OFF, you need to hold or
release motor brake. If you do not appropriately adjust the timing,
instantly load drops occurs in the device.
Initial Torque Bias
Falling by gravity
Load