Tuning by Gain Setting
8-5
CSD7 Servo Drive (EtherCAT)
Inertia Ratio
What is Inertia Ratio ?
The following figure explains the inertia ratio.
It shows the ratio of load inertia compared to the motor (rotor)
inertia.
If the motor (rotor) inertia is 3 [gf·cm·s²] and the load inertia is 30 [gf
·cm·s²], the inertia ratio is 10 times. For the motor inertia table, refer
to the motor specification.
Setting Unit
Setting value of Inertia Ratio uses the unit, [times]. For example, if
the motor inertia is same as the load inertia, the Inertia Ratio is 1
[time] and the setting value is 1.00.
The setting value of the Inertia Ratio is determined by the following
formula.
𝐼𝐼𝐼𝐼𝐼𝐼𝐼
𝑅𝐼𝐼𝐼𝑅
[
𝐼𝐼𝑡𝐼𝑡
] =
𝐿𝐿𝐿𝐿
𝐼𝐼𝐼𝐼𝐼𝐼𝐿
𝑀𝐿𝐼𝐿𝐼
𝑅𝐿𝐼𝐿𝐼
𝐼𝐼𝐼𝐼𝐼𝐼𝐿
Motor Inertia
Load Inertia
Содержание OEMax CSD7
Страница 1: ...CSD7 Servo Drive User Manual Catalog Number s CSD7_ BN F 1 EtherCAT Network type ...
Страница 4: ......
Страница 12: ...viii CSD7 Servo Drive EtherCAT SAFETY FUNCTION CONNECTOR B 6 ...
Страница 23: ...Preface P 11 CSD7 Servo Drive EtherCAT ...
Страница 24: ......
Страница 33: ...Installation 2 5 CSD7 Servo Drive EtherCAT 100W 200W 400W 800W 1KW 1 5KW ...
Страница 38: ......
Страница 76: ......
Страница 94: ......
Страница 114: ......
Страница 126: ......
Страница 314: ......
Страница 320: ...A 6 Specification and Exterior Dimensions CSD7 Servo Drive EtherCAT FigureA 5 400W FigureA 6 800W 1 5KW ...
Страница 327: ...able and Connector Specification B 5 CSD7 Servo Drive EtherCAT ...
Страница 330: ......
Страница 331: ...Publication CSD7 UM001A Network EN October 2015 ...
Страница 332: ...Copyright 2015 RS Automation Co Ltd All rights reserved ...