Pressure Pump™

TPP-750 User Manual

Содержание TP-750-2

Страница 1: ...RPS Tankless Pressure Pump TPP 750 User Manual ...

Страница 2: ......

Страница 3: ......

Страница 4: ...tinuous steady reliable water pressure without the need for AC power or the utility grid The solar charged battery bank powers a centrifugal booster pump that varies its speed and power based on your demand for water at the exact pressure you select from 20 to 45psi ...

Страница 5: ...check valve so you can pour water in the top and fill the chamber easily PRIMING VIDEO Very Helpful http www youtube com c RPSSolarPumps PRIMING YOUR PUMP TPP PLUMBING OPTIONS Important Care should be taken when plumbing to ensure tight connections and maintain prime Use teflon tape or thread sealant on all connections Minor leaks or seepage will cause the pump to cycle and deplete the batteries Y...

Страница 6: ... Liquid Temp 90 C 194 F Weight 10kg 22lbs TPP PUMP DIMENSIONS Compatible Pump TP 750 Only Battery Voltage 24 VDC Only Battery Wiring 10AWG or Thicker Dimensions 300mm x 270mm x 95mm 12in x 11in x 4in Temp Range 0 40 C 32 104 F OPTIONAL AC INPUT See 220v Wiring 220 VAC Only Weight 2 17kg 4 8lbs Recommended Clearance Mount with 12 inches of space in all directions TPP CONTROLLER DIMENSIONS ...

Страница 7: ...t running increases the lifetime of the system TPP PUMP Your pump is designed for use out of the direct elements sun rain and snow Covering or building into a small enclosure is ideal Since water does expand when it freezes care should be taken to winterize the system if being used in a climate that experiences hard freezing If foot valve is being used care should be taken in plumbing the intake t...

Страница 8: ...solar panels together and connect to the controller by clipping MC4 connectors together Each MC4 connector is either a male end or female end see image They simply snap together to make safe and easy connections Note If using your own solar panels do not exceed 55Voc input ...

Страница 9: ...ears of operation They should also be stored in a dry location protected from the elements To prevent significant voltage drop the batteries should be located as close to the Controller as possible Within 3 feet is ideal If further than 3ft is required the wires may be extended using appropriate gauge cables The batteries operate best at room temperature and it is best to keep them out of freezing...

Страница 10: ...20V AC to both charge your batteries and run your pump directly if desired There is a 3 prong outlet and a pigtail in your kit that allows for the wiring of 220v line power connector Wiring 220v is only for certified professionals or those familiar with 220v power Green Stripe Wire GROUND Blue or Black Wire L1 HOT Yellow or Red Wire L2 HOT Wire out or cap your neutral wire L1 L2 G ...

Страница 11: ...5PSI on a the second story of a house 3 TIMER Operates for the specified amount of time and then stops the pump Used for filling elevated tanks LOCK UNLOCK Hold and together SYSTEM RESET OPTIONS POWER RESET Controller Soft Reset Turn off controller power button display will stay on if solar panels are connected wait 60 seconds and turn power button back on Controller Hard Reset Disconnect solar pa...

Страница 12: ...creen Initialization Screen may flash fault 18 when unit is restarting due to low input voltage Your Controller is not waterproof and should be located in a dry dust free location protected from the sun and the elements and pests such as mice moths and bugs Mice love to chew wires and spiders and moths will build nests wherever they can find room While we understand you cannot eliminate all pests ...

Страница 13: ...voltage Check battery voltage E02 Over voltage input Ensure input voltage is less than 280V AC E03 Pressure sensor error Hard Reset Replace pressure sensor E04 Pump over temperature Remove pump from direct sun Improve ventilation E05 Pump Overload Ensure water is fairly clear no mud or large debris E06 Display over temperature or sensor failure Remove from direct sun Improve ventilation Hard reset...

Страница 14: ...The warranty is limited to the repair or replacement of the product Rural Power Systems Inc disclaims all liability for indirect and or consequential damages such as any installation charges damage to mounting structures buildings or loss of revenue The warranty does not apply when the equipment has not been installed according to the instructions or damage has occurred through abuse carelessness ...

Страница 15: ..._ ___________________________________________________________________ ___________________________________________________________________ ___________________________________________________________________ ___________________________________________________________________ ___________________________________________________________________ __________________________________________________________...

Страница 16: ...RPS Solar Pumps 40250 County Rd 27 Woodland CA 95776 888 637 4493 Call or Text ...