PX4 AIR

®

use the FR (Fire Retardant) specific model of the PX4 AIR

®

 with the FR belt and spark arrester. 

The PX4 AIR

®

 must always be used with the correct filter(s), the front cover and the prefilter 

cover to form a complete system. An incomplete system could provide inadequate respiratory 
protection. 

See Respirator Setup and Care  (page 12). 

VERIFY THAT YOU HAVE THE APPROPRIATE EQUIPMENT FOR YOUR ACTIVITY

Verify that the PX4 AIR

®

 provides appropriate protection for your activity. As applicable, check 

your workplace safety program, respiratory protection program, and standards and regulations for 
your activity or industry. (See PROTECTION PROVIDED AND LIMITATIONS, page 4.) 

BEFORE DONNING THE PX4 AIR

®

:

Verify airborne contaminants are within recommended limits for respirator use:

 Determine the type and level of contamination. Verify that airborne contaminant 

concentrations do not exceed those allowed by applicable OSHA, EPA, or NIOSH 
regulations and recommendations for powered air purifying respirators or supplied air 
respirators.

Select the correct filter cartridge for the contamination and application:

 

PAPR:

 Once the contamination level has been confirmed, determine the correct filter 

cartridge to be used for the application, to make sure that you are sufficiently protected. 

Make sure the area is ventilated and monitored:

 Make sure that the area is well ventilated and that regular air samples are taken to 

confirm the atmosphere stays within the levels recommended by OSHA and other 
governing bodies. 

If you have any questions, ask your employer.

DO NOT ENTER THE WORK AREA

 if any of the following conditions exist:

 Atmosphere is immediately dangerous to life or health.

 You cannot escape without the aid of the respirator.

 Atmosphere contains less than 19.5% oxygen.

 If flammable or explosive atmosphere is present. This system contains electrical parts that 

are not suitable for use in such environments. The PX4 AIR

®

 is not intrinsically safe.

 Contaminants are in excess of regulations or recommendations.

 Contaminants or contaminant concentrations are unknown.

 Work area is poorly ventilated. 

 The work area is a confined space (unless proper measures are taken).

 The temperature is outside the range of 14°F to 131°F (-10°C to +55°C).

LEAVE THE WORK AREA IMMEDIATELY IF:

 Any product component becomes damaged. 

 Vision is impaired.

PRODUCT USER SAFETY INSTRUCTIONS 

CONTINUED

Содержание NIOSH PX4 AIR

Страница 1: ...uct users Read this manual and the respirator head top Instruction Manual and follow the Product User Safety Instructions page 9 Manuals are regularly updated Make sure this manual is available to all...

Страница 2: ...ON AND CLEANING 25 PRODUCT SPECIFICATIONS AND DATA 27 PARTS AND ACCESSORIES 28 WARRANTY AND LIABILITY STATEMENT 30 CONTENTS EXPLANATION OF SIGNAL WORDS AND SYMBOLS The following signal word and safety...

Страница 3: ...ctual Property means any patent patented articles patent applications designs industrial designs copyrights software source code database rights moral rights inventions techniques technical data trade...

Страница 4: ...lations or recommendations Contaminants or contaminant concentrations are unknown PROTECTION PROVIDED AND LIMITATIONS Improper selection fit use or maintenance of this product can result in injury lif...

Страница 5: ...not intrinsically safe AIR SOURCE Powered Air Check that the contaminated area is within the limits of use for a Powered Air Purifying Respirator and determine the type of contamination Once the cont...

Страница 6: ...for hoods and or helmets I Contains electrical parts that may cause an ignition in flammable or explosive atmospheres J Failure to properly use and maintain this product could result in injury or dea...

Страница 7: ...n should determine what kind of respiratory face and eye head and hearing protection is appropriate for the intended activities and environments of use For example select a respirator appropriate to t...

Страница 8: ...e work area Measure and monitor airborne contaminant levels in the work area in accordance with applicable requirements Make sure work area is well ventilated Exposure limits for mixtures The American...

Страница 9: ...PX4 AIR PAPR See Respirator Component Diagram page 6 See the instruction manual and approval label for the selected head top for NIOSH approval with the PX4 AIR and the assigned protection factor Use...

Страница 10: ...ation and application PAPR Once the contamination level has been confirmed determine the correct filter cartridge to be used for the application to make sure that you are sufficiently protected Make s...

Страница 11: ...sure to use the FR Fire Retardant specific model of the PX4 AIR with the FR belt and spark arrestor in place see Respirator Setup and Care page 12 Confined Spaces If this respirator is used in confine...

Страница 12: ...well ventilated place where the charger can be monitored and easily observed during charging Battery care Do not use the battery outside the recommended temperature limits 14 F to 131 F 10 C to 55 C...

Страница 13: ...ss The triangle warning light will indicate when there is a problem charging When all three lights display green the battery is fully charged FIGURE 2 3 FIGURE 2 4 Fit the battery to the charging stat...

Страница 14: ...ce Life of HE Filter Prefilter and Spark Arrestor The HE filter should be replaced if the airflow alarm is activated or the flow indicator reading falls below the 6cfm 170 slpm minimum airflow The HE...

Страница 15: ...as you face it rotate the door to the left and latch in place In environments with sparks such as welding or grinding use the 03 982 Spark Arrestor in front of the 03 981 Prefilter This will reduce t...

Страница 16: ...oor off the latch 1 2 Remove the 03 985 filter from the Door and dispose of it in a suitable way Install the new replacement 03 985 filter as per Fig 3 3 and 3 4 Inspect the 03 981 Prefilter and repla...

Страница 17: ...breathing tube clockwise a turn to lock into position Make sure that it is fully locked in position BREATHING TUBE Select the flexible breathing tube that suits your respirator head top check that th...

Страница 18: ...r 04 091 is in the safe range before use so that there is sufficient air flow POWER BUTTON AND BATTERY INDICATION The top row of green lights indicate the charge of the battery 3 lights is fully charg...

Страница 19: ...annot be achieved Blocked Speed 1 cannot be achieved Speed 240 slpm The blue lights indicate the selected fan speed The red lights indicate the level of blockage When the lights flash red and blue the...

Страница 20: ...a new one LOW BATTERY CHARGE ALARM A pulsing alarm sounds when approximately 10 15 minutes of charge is left in the battery Leave the work area Power the unit off and remove the battery and place on...

Страница 21: ...Welding grinding where sparks may be present and High Heat Applications BELT AND SUPPORT ATTACHMENT Take the loose end of the Belt and thread from behind through the outer slot slot furthest out from...

Страница 22: ...sure that the battery is securely fitted to the PX4 AIR PAPR 3 BREATHING TUBE Inspect the breathing tube completely looking for splits and cracks in the tube the fittings are held securely in the tub...

Страница 23: ...e button after 5 10 seconds indicating that the airflow is below the minimum airflow Remove your hand and the alarm and LED should return to normal operation once the airflow is back to safe levels 7...

Страница 24: ...contained RESPIRATOR SETUP AND CARE CONTINUED AIR FLOW Speed 1 Greater than 6cfm 170slpm Speed 2 Greater than 7 4cfm 210slpm Speed 3 Greater than 8 4cfm 240slpm OPERATING TEMPERATURE 14 F to 131 F 10...

Страница 25: ...urations Note you should consult with your transport specialist before transporting Lithium ion batteries BATTERY CHARGING 3 hours PRODUCT STORAGE LIFE from new if kept in original sealed packaging A...

Страница 26: ...26 PX4 AIR PARTS AND ACCESSORIES FIGURE 9 1 1 3 2 4 5 7 8 9 10 11 10 13 6 14 15 16 17 12...

Страница 27: ...C Power Cable AU 2 pin 09 021 AU 16 24 Volt Power Supply with Power Cord 03 952 24 Volt Power Supply with Power Cord AU 03 952 AU 24 Volt Power Supply with Power Cord EU 03 952 EU 24 Volt Power Supply...

Страница 28: ...ect occurs RPB will repair or replace the defective Product or a component of the Product in its sole discretion This repair or replacement remedy is the sole and exclusive remedy under this limited w...

Страница 29: ...29 NOTES...

Страница 30: ...esigned to increase your productivity RPB T LINK Built off the Z Link platform the T Link is designed to work with you not against you Gone are the days of having to fight against a Tyvek respirator T...

Отзывы: