background image

RGM-1000 

 

4

Figure 2 Installation of car cigarette power adaptor 

 

 

 

 

 

 

 

 

 

 

 

 

Notice:  

(1)  Make sure the power is off before started.   

(2)  For safety reason, please do not install RGM-1000 while driving. 

(3)  To receive NMEA0183 navigational data, please use the Hyper Terminal program of Windows 

95/98

. Please setup the COM port connected with Navi@Mouse to: 

Baud rate 

: 4800 

Data bit 

: 8   

Parity : 

None 

Stop bit 

: 1 

Flow control 

: None. 

 

(4)  The formats of NMEA messages are illustrated on Software Data section. 

(5)  To prevent from the poor contact, the 4-pin mini din connector was designed as good fitting. It is 

strongly recommend that user doesn’t plug and unplug this connector frequently. 

 

RS-232

 

 

PS2

 

 

Cigarette 

power adaptor 

Содержание Navi@Mouse

Страница 1: ...Navi Mouse GPS Receiver User Manual ...

Страница 2: ...232 3 How to Install Operate Navi Mouse USB for Windows 98 5 How to Install Operate Navi Mouse USB for Windows Me 11 How to Install Operate Navi Mouse USB for Windows 2000 15 How to test your Navi Mouse 24 Specifications 28 Position update rate 29 Software Data 30 Troubleshooting 35 Appendix Connector Interface 36 Limited Warranty 37 ...

Страница 3: ...er immediately Please refer to the contact information on the last page of this manual GPS Receiver Application CD Cable for RS232 or USB depending on what you buy What Is GPS In 1974 the USA Department of Defense started development of the Global Positioning System GPS a constellation of 24 satellites that orbit 12 000 miles above the Earth By triangulating the signals from four of the satellites...

Страница 4: ...ur Navi Mouse on the outside roof of your vehicle with magnetic base Figure 1 Installation of PS2 RS 232 Step 4 Power on your Notebook PC or Handheld PC If you have ordered a cigarette adaptor please plug the cigarette adaptor into the cigarette outlet of the car Step 5 Choose the correct COM port for running the map or navigation software Step 6 Run the Navi mouse test program Please refer to How...

Страница 5: ... Terminal program of Windows 95 98 Please setup the COM port connected with Navi Mouse to Baud rate 4800 Data bit 8 Parity None Stop bit 1 Flow control None 4 The formats of NMEA messages are illustrated on Software Data section 5 To prevent from the poor contact the 4 pin mini din connector was designed as good fitting It is strongly recommend that user doesn t plug and unplug this connector freq...

Страница 6: ...RGM 1000 5 How to Install Operate Navi Mouse USB for Windows 98 Getting Started Step 1 Plug USB connector to USB port of your Notebook PC or Handheld PC USB ...

Страница 7: ...0 6 Step 2 After plug in the Navi Mouse it will automatically detect the hardware and show up pop up dialog as follows Click Next button Assert the Search for the best driver for your device Click Next button ...

Страница 8: ...000 7 Please assert the Specify a location and select the correct directory of the driver USB_DRIVER in CD Disc Click the Next button It will find the driver from the CD Disc automatically Click Next button ...

Страница 9: ...RGM 1000 8 The USB Serial converter driver is installed now You can check the COM port number of Navi Mouse from the System properties now ...

Страница 10: ...ap or navigation software Step 6 Run the Navi mouse test program Please refer to How to test your Navi mouse Notice 1 Make sure the power is off before started 2 For safety reason please do not install RGM 1000 while driving 3 To receive NMEA0183 navigational data please use the Hyper Terminal program of Windows 95 98 Please setup the COM port connected with Navi Mouse to Baud rate 4800 Data bit 8...

Страница 11: ...83 data formats are illustrated on Software Data section 5 To prevent the poor contact the 4 pin mini din connector was designed as good fitting We strongly recommend user that do not plug and draw this connector frequently ...

Страница 12: ...onnector to USB port to your Notebook PC or Handheld PC Step 2 After plug in the Navi Mouse it will detect the hardware automatically Click the Next button Please assert the Specify a location and select the correct directory of the driver in CD Disc USB_DRIVER Click the Next button ...

Страница 13: ...000 12 Windows Me will search and find the USB serial driver Click Next button The USB Serial converter driver is installed now You can check the COM port number of Navi Mouse from the System properties now ...

Страница 14: ...tware Step 6 Run the Navi mouse test program Please refer to How to test your Navi mouse Notice 1 Make sure the power is off before started 2 For safety reason please do not install RGM 1000 while driving 3 To receive NMEA0183 navigational data please use the Hyper Terminal program of Windows Me Please setup the COM port connected with Navi Mouse to Baud rate 4800 Data bit 8 Parity None Stop bit 1...

Страница 15: ...83 data formats are illustrated on Software Data section 5 To prevent the poor contact the 4 pin mini din connector was designed as good fitting We strongly recommend user that do not plug and draw this connector frequently ...

Страница 16: ...ndows 2000 Step 1 Plug USB connector to USB port to your Notebook PC or Handheld PC Step 2 After plug in the Navi Mouse it will detect the hardware automatically Click the Next button Please select Search for a suitable driver for my device Click Next button ...

Страница 17: ...RGM 1000 16 Please select the Specify a location Click Next button Please browse the CD Disc and select the directory USB_DRIVER Click OK button ...

Страница 18: ...RGM 1000 17 ...

Страница 19: ...RGM 1000 18 Windows 2000 will find the USB Serial converter device Click the Next button The USB Serial driver is installed in Windows 2000 now ...

Страница 20: ...RGM 1000 19 It will setup the USB Serial port driver for Navi Mouse Please click Next button Please select the Search for a suitable driver for my device Click Next button ...

Страница 21: ...RGM 1000 20 Please select the Specify a location Click Next button Please select the directory of the Navi Mouse USB_DRIVER Click OK ...

Страница 22: ...RGM 1000 21 It will find the driver and install it The USB Serial Port driver is installed in Windows 2000 now ...

Страница 23: ...t COM port for running the map or navigation software Step 6 Run the Navi mouse test program Please refer to How to test your Navi mouse Notice 1 Make sure the power is off before started 2 For safety reason please do not install RGM 1000 while driving 3 To receive NMEA0183 navigational data please use the Hyper Terminal program of Windows 2000 Please setup the COM port connected with Navi Mouse t...

Страница 24: ...83 data formats are illustrated on Software Data section 5 To prevent the poor contact the 4 pin mini din connector was designed as good fitting We strongly recommend user that do not plug and draw this connector frequently ...

Страница 25: ...ram by double clicking the Test programs Demo Navi mouse setup exe file Then the test program will automatically install into your computer 2 Run the testing program by clicking the shortcut on your Window s program group 3 Testing program will display as follow ...

Страница 26: ...ing the test program make sure you have connected Navi Mouse to the PC correctly 5 Click the icon on toolbar or click the Start test on the Setup menu Then the program will automatically detect the serial port and start testing ...

Страница 27: ...test there is a message box showing the test result If the test is successful it will show the following message If the test fails it will show the following message If it cannot open the COM port it will show the following message ...

Страница 28: ...RGM 1000 27 7 If the GPS connection is successful you can see the satellite tracking diagram and the updated data of longitude latitude altitude date time etc ...

Страница 29: ... mm H Weight 180 grams Temperature characteristics Storage temperature 20 70 Operating temperature 20 80 General Sensitivity 141 dBm Channels 12 channels L1 1575 42 MHz C A code 1 023MHz chip rate Accuracy Position accuracy 10m 90 without SA Velocity accuracy 0 1 meter second without SA ...

Страница 30: ... second Dynamic conditions Altitude 18000 meters 60000 feet max Velocity 514 meters second max Jerk 20 meters second3 max Acceleration 4 G max Power PS2 USB input power DC 5V 5 210mA typical Car cigarette power adaptor 9V 16V Certification FCC CE compliant ...

Страница 31: ...lues of the following example GPGGA 161229 487 3723 2475 N 12158 3416 W 1 07 1 0 9 0 M 0000 18 Table 2 GGA Data Format Name Example Units Description Message ID GPGGA GGA protocol header UTC Position 161229 487 hhmmss sss Latitude 3723 2475 ddmm mmmm N S Indicator N N north or S south Longitude 12158 3416 dddmm mmmm E W Indicator W E east or W west Position Fix Indicator 1 See Table 5 1 Satellites...

Страница 32: ...RGM 1000 31 ...

Страница 33: ... example GPGSA A 3 07 02 26 27 09 04 15 1 8 1 0 1 5 33 Table 3 GSA Data Format Name Example Units Description Message ID GPGSA GSA protocol header Mode 1 A See Table 3 2 Mode 2 3 See Table 3 1 Satellite Used1 07 Sv on Channel 1 Satellite Used1 02 Sv on Channel 2 Satellite Used1 Sv on Channel 12 PDOP 1 8 Position Dilution of Precision HDOP 1 0 Horizontal Dilution of Precision VDOP 1 5 Vertical Dilu...

Страница 34: ...e 4 GSV Data Format Name Example Units Description Message ID GPGSV GSV protocol header Number of Messages1 2 Range 1 to 3 Messages Number1 1 Range 1 to 3 Satellites in View 07 Satellite ID 07 Channel 1 Range 1 to 32 Elevation 79 degrees Channel 1 Maximum 90 Azimuth 048 degrees Channel 1 True Range 0 to 359 SNR C No 42 dBHz Range 0 to 99 null when not tracking Satellite ID 27 Channel 4 Range 1 to ...

Страница 35: ...mple Units Description Message ID GPRMC RMC protocol header UTC Position 161229 487 hhmmss sss Status A A data valid or V data not valid Latitude 3723 2475 ddmm mmmm N S Indicator N N north or S south Longitude 12158 3416 dddmm mmmm E W Indicator W E east or W west Speed Over Ground 0 13 knots Course Over Ground 309 62 degrees True Date 120598 ddmmyy Magnetic Variation degrees E east or W west Che...

Страница 36: ... program Close all the other application programs and rerun the Navi Mouse Testing program There is nothing showing on the tracking diagram even if the test result is success Navi Mouse can not receive the GPS signal on the testing area Move Navi Mouse to somewhere there is exposed to outdoors Note normally we cannot receive the GPS signal indoors No position output but timer is counting 1 Weak or...

Страница 37: ...nect 8 No connect 9 No connect 6 pin mini din Pin NO Signal Name I O Description Characteristics 1 No connect 2 No connect 3 GND G Ground 4 VCC I 5V DC Power Input DC 5V 10 5 No connect 6 No connect USB A Type Connector Pin NO Signal Name I O Description Characteristics 1 GND Ground Ground 2 D I O Data plus Data plus 3 D I O Data Minus Data Minus 4 VCC 5V DC Power Input 5V DC Power Input Notice Th...

Страница 38: ... In such case the defective unit will be repaired or replaced according to an assessment by RoyalTek However this warranty does not cover damages caused by improper use or from unauthorized modifications by third parties In addition this warranty does not cover expendable materials and defects which constitute as normal wear or tear Please contact us as following RoyalTek 1071 Chung Cheng Rd Suite...

Отзывы: