FAVORITE POSITIONING

SET A FAVORITE POSITION

SEND SHADE TO FAVORITE POSITION

DELETE A FAVORITE POSITION

Move shade to the desired position by pressing the 

UP

 or 

DOWN

 button on the controller.

Press 

STOP 

on controller for 2 seconds.

Press 

STOP

 on controller.

Press 

STOP

 on controller.

Press 

P2

 on controller.

or

Motor Response

Motor Response

Motor Response

Press 

STOP

 on controller.

Press 

STOP

 on controller.

Press 

P2

 on controller.

Approx.

Motor Response

Motor Response

Motor Response

Содержание R TEC AUTOMATION RTMDC25

Страница 1: ...ble in three motor sizes DC wired shades are maintenance free and the AC power supply adapter keeps installation costs to a minimum They offer a low voltage easy to use and program solution to suit a...

Страница 2: ...eck Motor Direction Set Limits Adjusting Limits 9 Adjust Upper Limit Adjust Lower Limit Adding or Removing Controllers Creating Group Channels 10 Using Motor P1 Button Using a Pre Existing Controller...

Страница 3: ...se harmful interference This device must accept any interference received including interference that may cause undesired operation Parameters Value for 25 mm Value for 28 mm Value for 35 mm TECHNICAL...

Страница 4: ...e with end application Do not expose the motor to water or install in humid or damp environments Motor is to be installed in horizontal application only Do not drill into motor body The routing of cab...

Страница 5: ...eration if the voltage drops to less than 10V the motor will beep 10 times to indicate a power supply issue Motor will stop running when the voltage is lower than 7V and it will resume again when the...

Страница 6: ...mit setting is completed first time If motor is in Sleep Mode limits are set Wake and control Motor wakes and runs in a direction None Motor is restored from Sleep Mode and RF control is active Hold P...

Страница 7: ...Motor Response PAIR MOTOR WITH CONTROLLER CHECK MOTOR DIRECTION PROGRAMMING INITIAL SET UP Motor is now in set up mode and ready for setting limits IMPORTANT Consult your user manual for information o...

Страница 8: ...r lowest position by pressing the UP or DOWN on the controller To save upper limit hold UP and STOP To save lower limit hold DOWN and STOP or Cycle shade up and down prior to setting limits to settle...

Страница 9: ...upper limit hold UP and STOP Hold UP and STOP on the controller Move shade to the desired highest position by pressing the UP button Move shade to the desired lowest position by pressing the DOWN butt...

Страница 10: ...CONTROLLER Press P2 on existing switch Press P2 a second time on existing switch Press P2 on new switch or remote controller Motor Response Motor Response Motor Response ADDING OR REMOVING CONTROLLER...

Страница 11: ...TE A FAVORITE POSITION Move shade to the desired position by pressing the UP or DOWN button on the controller Press STOP on controller for 2 seconds Press STOP on controller Press STOP on controller P...

Страница 12: ...on controller Press UP on controller Press UP on controller Motor Response Motor Response If motor does not react to speed adjustment the maximum speed has already been reached IMPORTANT Motor Respons...

Страница 13: ...ed trademark of the Rowley Company LLC 13 STEP ROLLER MODE ENTER STEP MODE ENTER ROLLER MODE DEFAULT Hold UP and DOWN on the controller Hold UP and DOWN on the controller Press STOP Press STOP Approx...

Страница 14: ...Rowley Company LLC 14 SLEEP MODE ENTER SLEEP MODE Sleep mode is utilized to prevent a motor from moving during shipping of a fabricated shade EXIT SLEEP MODE Hold P1 button on motor head Motor Respon...

Страница 15: ...incorrectly into transmitter Check battery polarity Radio interference Shielding Ensure transmitter is positioned away from metal objects and that antenna on motor or receiver is kept straight and awa...