JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 29 of 48
Features Menu
The Features Menu is accessed by holding the
UP and DOWN buttons
at the same time when the processor is
first powered up. Keep holding the
UP/DOWN buttons
through the INTERNAL SELF TEST screen, until the
processor displays a screen similar to the following:
FEATURES
1. Traceability OFF
Use the
UP/DOWN buttons
to highlight the desired option. Press the
START button
to access the desired
option. Press the
STOP button
to return to normal operation.
Traceability
This setting controls the Pipe/Fitting Traceability functions. Values are “OFF”, “ON” or “OPT”:
•
“OFF” disables the Pipe/Fitting Traceability function.
•
“ON” enables the Pipe/Fitting Traceability function. The machine WILL NOT allow a fusion to proceed
unless at least one (1) traceability barcode is scanned.
•
“OPT” (Optional) enables the Pipe/Fitting T
raceability function but will allow a fusion to proceed if the
operator decides not to scan a traceability barcode.
When Option 1 is highlighted, press the
START button
to select it. Use the
UP/DOWN buttons
to toggle
through available Pipe/Fitting Traceability function values. When the desired value is displayed, press the
START button
to save.
PIPE AND FITTING TRACEABILITY WILL ONLY APPLY TO FUSIONS DONE IN BARCODE MODE.
To learn more about Pipe and Fitting Traceability, contact an authorized representative (See page 15).
Содержание Jackman Fusion Equipment
Страница 1: ......
Страница 2: ......
Страница 49: ...JACKMAN FUSION EQUIP ELECTROFUSION PROCESSOR OPERATORS MANUAL REV 0 Page 47 of 48 Page Intentionally Left Blank...
Страница 50: ...JACKMAN FUSION EQUIP ELECTROFUSION PROCESSOR OPERATORS MANUAL REV 0 Page 48 of 48 Page Intentionally Left Blank...
Страница 51: ......
Страница 52: ...JACKMAN FUSION EQUIPMENT 715 S 59th Ave W Duluth MN 55807 USA www jackmanfusion com 218 302 4770...