3. Move the plunger rod (7) forward and backward to remove any trapped air pockets.
4. Tap the manual air release valve (9) again to release the trapped air. The grease gun is now
ready to use.
Before Each Use
Before using the grease gun, check that all connections are secure and that all parts of the product
are in good working condition.
Operating Instructions
⚠
WARNING
•
Always wear the proper protective equipment, including ANSI Z87.1 compliant eye protection.
•
High Pressure Fluid Hazard. Do not use a hose pressure rating that is less than the grease gun.
•
Do not exceed the max pressure of 10000 PSI.
•
Ensure that the trigger is in the OFF position when connecting to the air supply.
The grease coupler (3) provided at the end of the rigid steel extension (4) has a jaw-type construction.
The coupler jaws will snap on to a grease fitting and maintain a tight fit. When connecting the grease
coupler (3) to the grease fitting:
1. Press the grease coupler (3) straight onto the grease fitting to form a snug fit.
2. Start operating the lever (5) with the grease coupler (3) and align it to the grease fitting as tightly
as possible.
3. Once greasing is completed, slightly tilt the grease coupler (3) and then twist and pull back.
4. The tilt-and-twist action will allow easy removal of the grease coupler (3) from the grease fitting.