Rotex RKHBRD011ADV17 RKHBRD014ADV17 RKHBRD016ADV17 Скачать руководство пользователя страница 7

RKHBRD011~0Y17

Indoor unit for air to water heat pump system and options

4P403582-1B – 2017.09

Operation manual

6

Selecting weather dependent set point operation

When weather dependent operation is active, the leaving water
temperature is determined automatically depending on the outdoor
temperature: colder outdoor temperatures will result in warmer water
and vice versa. The unit has a floating set point. Activating this
operation will result in a lower power consumption than use with a
manually fixed leaving water set point.

During weather dependent operation, the user has the possibility to
shift up or down the target water temperature by a maximum of 5°C.
This shift value is the temperature difference between the
temperature set point calculated by the controller and the real set
point. E.g. a positive shift value means that the real temperature set
point will be higher than the calculated set point.

It is advised to use the weather dependent set point because it
adjusts the water temperature to the actual needs for space heating.
It will prevent the unit from switching too much between thermo ON
operation and thermo OFF operation when using the remote
controller room thermostat or external room thermostat.

1

Press the 

 button 1 time to select weather dependent set

point operation (or 2 times when the remote controller room
thermostat function is used).

Icon 

 appears on the display as well as the shift value. The

shift value is not shown in case it is 0.

2

Use the 

 and 

 buttons to set the shift value.

Range for the shift value: –5°C to +5°C

Icon 

 will be displayed as long as the weather dependent set

point operation is enabled.

3

Press the 

 button to deactivate weather dependent set point

operation.

The 

 and 

 buttons are used to set the leaving

water temperature.

Field settings define the parameters for the weather dependent
operation of the unit. Refer to the chapter 

"Field settings" on page 16

for a detailed description how to set one or more field settings.

[3-00]

 Low ambient temperature (Lo_A): low outdoor

temperature.

[3-01]

 High ambient temperature (Hi_A): high outdoor

temperature.

[3-02]

 Set point at low ambient temperature (Lo_Ti): the target

outgoing water temperature when the outdoor temperature
equals or drops below the low ambient temperature (Lo_A).

Note that the Lo_Ti value should be higher than Hi_Ti, as for
colder outdoor temperatures (i.e. Lo_A) warmer water is required.

[3-03]

 Set point at high ambient temperature (Hi_Ti): the target

outgoing water temperature when the outdoor temperature
equals or rises above the high ambient temperature (Hi_A).

Note that the Hi_Ti value should be lower than Lo_Ti, as for
warmer outdoor temperatures (i.e. Hi_A) less warm water
suffices.

Automatic setback function

Setback function provides the possibility to lower the room
temperature. The setback function can for instance be activated
during the night because the temperature demands during night and
day are not the same.

The setback function is configured through field settings. Refer to the
chapter 

"Field settings" on page 16

 for a detailed description how to

set one or more field settings.

[2-00]

 Status: defines whether the setback function is turned ON

(1) or OFF (0)

[2-01]

 Start time: time at which setback is started

[2-02] 

Stop time: time at which setback is stopped

[5-02] 

Leaving water setback temperature (temperature drop)

NOTE

During this operation, instead of showing the water
temperature set point, the controller shows the shift
value which can be set by the user.

T

t

Target water temperature

T

A

Ambient (outdoor) temperature

= Shift value

Lo_Ti

Lo_A

Hi_A

T

A

T

t

+ 05

00

– 05

Hi_Ti

Shift value

NOTE

If by mistake the value of [3-03] is set higher than the
value of [3-02], the value of [3-03] will always be used.

NOTE

Remark that the   icon will be flashing during
setback operation.

By default the setback function is enabled.

The setback function can be combined with the
automatic weather dependent set point operation.

Setback function is an automatic daily scheduled
function.

A

Normal leaving water temperature set point

B

Leaving water temperature, including the leaving water setback 
temperature

t

Time

T

Temperature

[2-01]

[2-02]

B

A

T

t

65

°

C

60

°

C

5

°

C [5-02]

4PEN403582-1B_2017_09.book  Page 6  Saturday, October 7, 2017  11:02 AM

Содержание RKHBRD011ADV17 RKHBRD014ADV17 RKHBRD016ADV17

Страница 1: ...RKHBRD011ADV17 RKHBRD014ADV17 RKHBRD016ADV17 RKHBRD011ADY17 RKHBRD014ADY17 RKHBRD016ADY17 Indoor unit for air to water heat pump system and options 4PEN403582 1B_2017_09 book Page 1 Saturday October...

Страница 2: ...d knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not pla...

Страница 3: ...ge on page 7 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual storage one time water heat up refer...

Страница 4: ...T AVAILABLE This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficient permission level or can mean that a slave...

Страница 5: ...case not zero will display 31 ROOM TEMPERATURE ADJUST BUTTONS and These multi purpose buttons are used to adjust the current room temperature set point in normal operation mode or in schedule timer p...

Страница 6: ...mode heating will be activated as required by the water temperature set point The set point can be set manually through the schedule timer or weather dependent automatic Selecting space heating operat...

Страница 7: ...e Lo_A low outdoor temperature 3 01 High ambient temperature Hi_A high outdoor temperature 3 02 Set point at low ambient temperature Lo_Ti the target outgoing water temperature when the outdoor temper...

Страница 8: ...dependent domestic water heating is turned ON 1 or OFF 0 If enabled the storage set point will be set weather dependent In case of a higher ambient temperature e g during summer time temperature of s...

Страница 9: ...storage temperature is reached It can also be stopped at any time by pushing the button NOTE If weather dependent domestic water heating is enabled b 02 the storage temperature will be set automatica...

Страница 10: ...there are no error conditions in leaving or returning water thermistors the heater kit can start to follow emergency operation Other operation modes Start up operation During start up the icon display...

Страница 11: ...ule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pressing the button Space heating R...

Страница 12: ...ve until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command may date from the d...

Страница 13: ...ram depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a daily basis Take your time to enter all data accurately Try to program the actions...

Страница 14: ...s to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water temperature Use the and buttons...

Страница 15: ...en action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted By pressing the button several times you return to previous steps in this procedure and finally return to normal op...

Страница 16: ...er action number than the one that is displayed E g when the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted Deleting a mode 1 Press the button...

Страница 17: ...for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2 Press the button t...

Страница 18: ...w ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day sel...

Страница 19: ...04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation related setting 25 25 37 1 C 02 No...

Страница 20: ...e information If the supply cord is damaged it must be replaced by the manufacturer its agent or similar qualified persons in order to avoid hazards During longer periods of standstill e g during summ...

Страница 21: ...4PEN403582 1B_2017_09 book Page 1 Saturday October 7 2017 11 02 AM...

Страница 22: ...4PEN403582 1B_2017_09 book Page 2 Saturday October 7 2017 11 02 AM...

Страница 23: ...4PEN403582 1B_2017_09 book Page 1 Saturday October 7 2017 11 02 AM...

Страница 24: ...nd Nos partenaires l tranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granic Na i partne i v zahrani http de rotex heating com ueber rotex international 4P4...

Отзывы: