3 Operation

Operation manual

5

R0 R035A4AA
Wall-mounted condensing boiler
3P469438-6D – 2017.07

▪ Virtual room temperature (with outdoor sensor)

▪ Domestic hot water set temperature

▪ System pressure (at standby mode)

3.3.2

To select the operation mode

The operation mode can be changed by pressing the "Mode" button
(

).

(5 s)

(5 s)

a

c

b

d

e

a

Central heating only mode

b

Standby mode

c

Summer mode

d

Winter mode

e

Full-off mode

3.3.3

Possible operation modes

Operation mode

Description

Central heating only mode

▪ Only central heating operation mode

is enabled.

▪ The  central  heating  temperature

setpoint  (which  setpoint  is  shown
depends 

on 

the 

system

configuration;  see 

"3.3.5  Possible

central heating operation modes" on
page  6

)  and  the 

  icon  is  shown

on the home screen.

▪ The    icon  blinks  if  central  heating

operation is active.

Standby mode

▪ Both  central  heating  and  domestic

hot  water  operation  modes  are
disabled.

▪ The  protection  functions  such  as

frost  protection  are  still  active  at
standby mode.

▪ The home screen shows the system

pressure, as well as the   icon.

Summer mode

▪ Only  domestic  hot  water  operation

mode  is  enabled.  Central  heating
operation  mode  is  disabled.  The
boiler  will  only  produce  heat  for
domestic hot water.

▪ The  domestic  hot  water  setpoint,

and  the 

  icon  is  shown  on  the

home screen.

▪ The 

  icon  blinks  if  domestic  hot

water operation is active.

Operation mode

Description

Winter mode

▪ Both  domestic  hot  water  operation

mode  and  central  heating  operation
mode  are  enabled.  The  boiler  can
produce domestic hot water, as well
as produce heat for central heating.

▪ The  central  heating  temperature

setpoint  (which  setpoint  is  shown
depends 

on 

the 

system

configuration;  see 

"3.3.5  Possible

central heating operation modes" on
page  6

),  and  the 

  icon,  as  well

as  the 

  icon  are  shown  on  the

home  screen.  When  domestic  hot
water  operation  is  active,  domestic
hot  water  setpoint  is  shown  on  the
home screen.

▪ The 

  icon  blinks  if  domestic  hot

water operation is active.

▪ The    icon  blinks  if  central  heating

operation is active.

Full-off mode

▪ Both  central  heating  and  domestic

hot  water  operation  modes  are
disabled.

▪ LCD  display  will  be  darkened  and

will  not  be  activated  with  any  user
interaction.

▪ The  protection  functions  such  as

frost protection are still active at full-
off mode.

▪ Full-off  mode  is  activated  and

deactivated  if  "Mode"  button  is
pressed for 5 seconds while boiler is
in any mode.

3.3.4

Changing temperature setpoints

Temperature setpoints can be changed with the Right/Left dials.

To change the central heating temperature
setpoint

1

Turn the left dial while you are at the home screen. The setpoint
screen  will  appear  as  shown  below  and  the  setpoint  can  be
adjusted by turning the left dial. 

Note: 

The   icon means you are

at the setpoint screen.

2

To apply changes done, wait for 3 seconds or press the "Enter"
button. Pressing the "Cancel" button cancels the changes done.

Содержание R2CND028A4AA

Страница 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler R2CND028A4AA R2CND035A4AA R2TND028A4AA R2TND035A4AA...

Страница 2: ...pply Filling loop R2CND028A4AA R2CND028 Instantaneous External R2CND035A4AA R2CND035 Instantaneous External Model Type Domestic hot water supply Filling loop R2TND028A4AA R2TND028 Storage tank Externa...

Страница 3: ...Do not damage or remove any seals on components Only qualified persons are allowed to alter sealed components Do not make any modifications on Boiler Gas water or power supply Flue system 2 4 Gas con...

Страница 4: ...oiler Status Description Standby When there is no heat demand the status indicator shows this with a kind of breathing pulsation of the blue and white LED Flame At the moment flame ignites for central...

Страница 5: ...ater operation is active Operation mode Description Winter mode Both domestic hot water operation mode and central heating operation mode are enabled The boiler can produce domestic hot water as well...

Страница 6: ...dial Increasing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature respectively The and icons are shown on the screen when central heating oper...

Страница 7: ...ling When an error occurs the normal behaviour of the user interface is interrupted and the status of the status indicator is affected However be aware that not all errors have the same effect on the...

Страница 8: ...dependency 1 1 2 or 24 U10 Room temperature setpoint used by ROTEX Opentherm room thermostat during night C 18 10 30 User settings menu Parameters detailed Description U00 When using outdoor sensor ab...

Страница 9: ...of your boiler with a damp cloth and a little solvent free soap CAUTION Sprays solvents or cleaning agents containing chlorine can damage the exterior the fittings or the control unit Do not use them...

Страница 10: ...eeded If problem repeats contact your service agent E1 66 Calibration conditions fault No reset needed Wait burner to restart If problem repeats contact your service agent E1 67 Missing calibration Pe...

Страница 11: ...Solution UA 66 BCC ID of internal EEPROM is inconsistent Contact your service agent UA 67 BCC is missing Contact your service agent UA 68 BCC is not compatible with PCB BCC ID Contact your service ag...

Страница 12: ...usland Our partners abroad Unsere Partner im Ausland Nos partenaires l tranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granic Na i partne i v zahrani http...

Отзывы: