Communicator | 3.05
22
5.3.1.3 Status Report
Upon a user request, Communicator sends a status report on basic house functions and animal
statistics. The report includes the following specifications:
•
Target Temp
•
Average Temp
•
Vent Level
•
Vent Mode (minimum ventilation, natural, tunnel)
•
Humidity
•
Weight (current average animal weight)
•
Pressure (static pressure)
•
Water Control (daily water consumption)
•
Feed Count (daily feed consumption)
•
Mortality
By default, the report only includes Target Temp, Average Temp, Vent Level and Humidity.
NOTE:
Platinum Controllers, Version 3.0 and higher, support this function.
To select the parameters:
1. Go to
SYSTEM > Advanced Setup > GSM
.
2. Use the
+/
- key to select the required parameter.
3. Press
Enter
to select/deselect the parameter.
4. Press Save.
The parameters are configured.
To receive a status report:
•
Receiving the Report for One House
?SX
> 'Send SMS' to the Communicator cell phone number.
?
= Start of message
S
= Status report
X
= Represents house number (can be any positive number from 1 - 64)
•
Receiving the Report for Several Houses
?SX#X#X
> 'Send SMS' to the Communicator cell phone number
?
= Start of message
S
= Status report
X
= Represents house number (can be any positive number from 1-64)
#
= Sign separates between every house number