background image

10

3 O  50/60 Hz.

MOTOR

1

3

5   

1

2

3

4

7

5
8
6
9

L1

PE

L2

L3

L1

A2

A1

L2

L3

T1

T2

T3

N.O.

N.O.

CONTROL BOX

OVERHEAD

LIMIT SWITCH

CONTACTOR
COIL

UP SWITCH

440-480V, 60Hz.  3Ø

400V, 480V 50Hz.  3Ø

3 O  50/60 Hz.

MOTOR

L1

PE

L2

L3

L1

A2

A1

L2

L3

1

3

5   

1

7

2

8

3

9

4

5
6

T1

T2

T3

N.O.

N.O.

208V, 220-240V

60Hz.  3Ø

CONTROL BOX

OVERHEAD

LIMIT SWITCH

CONTACTOR
COIL

UP SWITCH

LOW VOLTAGE CONNECTION

HIGH VOLTAGE CONNECTION

T1

T2

T3

T4

T5

T6

T7

T9

T8

L1

L2

L3

L1

L2

L3

T1

RED

T2

BLUE

T3

WHITE

T4

BLACK "R"

T5

BLACK "S"

L
E
G
E
N
D

T6

BLACK "T"

T7

BROWN

T8

YELLOW

T9

GREEN

T1

WHITE

T2

RED

T3

BROWN

T4

WHITE

T5

RED

L
E
G
E
N
D

T6

BLACK

T7

WHITE

T8

RED

T9

BLUE

Two different wiring colors were used. Determine appropriate LEGEND.

T1

T2

T3

T4

T5

T6

T7

T9

T8

Fig. 16

NOTES:

1. Unit not suitable for use in unusual conditions.  Contact

Rotary for moisture and dust environment duty unit.

2. Control Box must be field mounted to power unit.
3. Requirements:

Use: FA7162 for 60 Hz. 208V Supply

FA7163 for 60 Hz. 220-240V Supply
FA7164 for 60 Hz. 440-480V or 50 Hz. 400V Supply
FA7165 for 50 Hz. 480V

4. *Verify Coil Rating Matches Supply Voltage
5. Motor rotation is counter clockwise from top of motor.

LINE VOLTAGE

208 - 230 Volts          60 HZ

460 Volts                    60 HZ

MOTOR OPERATING DATA - THREE PHASE

197        -       253 Volts

414        -       506 Volts

RUNNING MOTOR VOLTAGE RANGE

Three Phase Rotary Power Unit

Содержание SPO9

Страница 1: ...t 200 Series Lifts V A L I D A T E D CERTIFIED B Y E T L Entire contents October 2000 by Rotary Lift All rights reserved IN20008 Rev P 10 04 00 I N S T A L L A T I O N I N S T R U C T I O N S SPOA7 Ca...

Страница 2: ...est wall Power Unit Passenger Side Wheel Spotting Dish NOTE Dimension is from Inside of Baseplate to Inside of Baseplate Fig 1a Fig 1b 3 10 1178mm 8 11 5 8 2734mm SPO9 15 381mm 2 5 737mm 6 0 1829mm mi...

Страница 3: ...se shoe shims are used at any of the column anchor bolts pack non shrink grout under the unsupported area of the column base Insure shims are held tightly between the baseplate and floor after torquin...

Страница 4: ...1 HHCS and 3 8 Flanged Locknuts Fig 4 Tighten bolts at center of overhead assembly 9 Power Unit First install 1 star washer onto one of the 4 5 16 18NC x 1 1 2 HHCS This is very important for groundin...

Страница 5: ...cknut 1 4 20NC x 2 HHCS 1 4 Locknut Spacer 1 4 20NC x 3 4 HHCS Star Lockwasher and Nut 111 3 8 7 3 4 SPO9 3 8 16NC x 3 4 HHCS Flanged Locknut 1 4 20NC x 2 HHCS 1 4 Locknut 1 4 20NC x 3 4 HHCS Star Loc...

Страница 6: ...l Vent Screw Fill Breather Cap Raise Switch Lowering Valve PUSH LEVER TO LOWER Branch Tee Power Unit Hose Overhead Hose ALLOW 2 SECONDS BETWEEN MOTOR STARTS FAILURE TO COMPLY MAY CAUSE MOTOR BURNOUT P...

Страница 7: ...elop a pressure tight seal CAUTIONOvertightening will damage fitting resulting in fluid leakage Adapter Hose Installation see Fig 9b 1 Install Pc 2 with hose clamps on power unit column side connectin...

Страница 8: ...left column and feed the end of the cable through the latch cable sheave slot so that the cable is now back outside the column Fig 13 F Route cable under the bottom side of the latch cable sheave Fig...

Страница 9: ...plunger Verify that Power Unit stops working when switch bar is raised and re starts when the bar is released MOTOR OPERATING DATA SINGLE PHASE LINE VOLTAGE RUNNING MOTOR VOLTAGE RANGE 208 230 Volts 6...

Страница 10: ...T3 BROWN T4 WHITE T5 RED L E G E N D T6 BLACK T7 WHITE T8 RED T9 BLUE Two different wiring colors were used Determine appropriate LEGEND T1 T2 T3 T4 T5 T6 T7 T9 T8 Fig 16 NOTES 1 Unit not suitable for...

Страница 11: ...sing clearance gap NOTE Once arm is installed in yoke pull up actuator pin and swing arm fully around being sure that the Restraint Gear and Gear Block always stay aligned If they do not stay aligned...

Страница 12: ...ar Block to mesh together Fig 18 17 Oil Filling Bleeding Use Dexron III ATF or Hydraulic Fluid that meets ISO 32 specifications Column Arm Pin Cotter Pin Arm Long Bumper Short Bumper Padded section of...

Страница 13: ...se lift to check equalizer cable tension Below carriage grasp adjacent cables between thumb and forefinger with about 15 lbs effort you should just pull the cables together Adjust at upper tie offs Fi...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...6502 Fax 812 273 6502 E mail userlink rotarylift com Web site www rotarylift com For Canada DOVER CORP CANADA LTD ROTARY LIFT DIVISION 130 Bridgeland Avenue Unit 210 Toronto Ontario M6A 1Z4 Phone 416...