Pre-installation Information

Before you begin…

Before  unpacking,  inspect  the  carton  for  exterior  damage.  If
you  find  damage,  advise  the  delivery  carrier  of  a  potential
claim.  Inspect  your  package  carefully .

Claims  for  shortages

will be honored for only 30 days from the date of shipment.

Before  installing  the  operator,  read  this  manual  completely  to
ensure  all  requirements  for  proper  installation  are  present.
Verify  that  the  voltage  to  be  used  matches  the  voltage  of  the
operator.

If  you  have  any  questions  about  the  requirements  for  proper
installation of this gate operator contact technical support at 1 -
877-331-4747.

Always Check the Gate’s Action

It’s  very  important  before  installing  the  gate  operator  to
make  sure  the  gate  slides  free  and  level  throughout  the
entire  opening  distance.  If  the  gate does  not  seem  to
operate  properly,  it  may  affect  the  operator  performance
or greatly shorten the life of the unit. The gate should also
be  designed  so  that  airflow  is  ample  to  prevent  wind
resistance and dra g.

Gate Operator Classifications

All  gate  operators  can  be  divided  into  one  of  four  different
classifications,  depending  on  their  design  and  usage.  Install
this gate operator only when the operator is appropriate for the
construction and usage class as defined below:

Class I Residential Vehicular Gate Operator

A vehicular gate operator intended for use in a home or for one to
four  single  family  dwellings  with  a  common  garage  or  parking
area associated with these dwellings.

Class II Commercial/General Access Vehicular Gate Operator

A  vehicular  gate  operator  intended  for  use  in  a  commercial
location  or  building  such  as  a  multi -family  housing  unit  of  five  or
more  single  family  units,  hotel,  retail  store  or  other  building
servicing the general public.

Class III Industrial/Limited access  Vehicular Gate Operator

A vehicular gate operator intended for use in an industrial location
or building such as a factory or loading dock area or other location
not intended to service the general public.

Class IV restricted Access Vehicular Gate Operato r

A vehicular gate operator intended for use in a guarded industrial
location  or  building  such  as  an  airport  security  area  or  other
restricted  access  locations  not  servic ing  the  general  public,  in
which  unauthorized  access  is  prevented  via  supervision  by
security personnel.

Approved Obstruction Detection Devices

The  following  contact  or  non -contact  obstruction  detection
devices  have  been  approved  for  use  with  this  slide  gate
operator as part of a UL325 compliant installation:

Contact Edges

Miller Edge Models MGR20, MGS20, ME120

Photoeyes

MMTC Model IR-55 (165’ range)
MMTC Model E3K (28’ range)

Safety Information and Warnings

THE  FOLLOWING  FORMATS  ARE  USED  FOR
SAFETY NOTES IN THESE INSTRUCTIONS.

Regulatory Warnings

Read  the  following  before  beginning  to  install  this  slide
gate operator:

WARNING

CAUTION

WARNING

This type of warning note is used to indicate
the possibility of damage to the gate or gate
operator.

This  type  of  warning  note  is  used  to
indicate possible mechanical hazards that
may cause serious injuries or death .

This  type  of  warning  note  is  used  to
indicate  possible  electrical  shock  hazards
that may cause serious injuries or death.

IMPORTANT INSTALLATION SAFETY  INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO

PERSONS, REVIEW THESE INSTALLATION SAFETY STEPS

BEFORE PROCEEDING

1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2. ALL  ELECTRICAL  CONNECTIONS  TO  THE  POWER

SUPPLY MUST BE MADE BY A LICENSED ELECTRICIAN
AND  MUST  OBSERVE  ALL  NATIONAL  AND  LOCAL
ELECTRICAL CODES.

3. A  separate  power-disconnect  switch  should  be  located  near

the  operator  so  that  primary  power  can  be  turned  off  when
necessary.

4. Install the enclosed warning signs on both sides of the gate.

A minimum  of two  (2)  warning  signs  shall  be  installed,  one
on each side of the gate where easily visible.

5. Never reach between, thro ugh or around the fence to operate

the gate.

6. Never connect a button station within reach of the gate or on

the side of the gate operator.

7. Do not adjust the operator controller’s current sensing feature

too high. It should be adjusted high enough to keep t he gate
from  falsely  triggering  the  sensing,  but  no  higher  than
necessary  for  the  gate  to  operate.  DO  NOT  DEFEAT  THE
PURPOSE OF THIS FUNCTION!

8. You must install all required safety equipment.
9. UL325  Compliance  requires  the  use  of  contact  edges  of

photoelectric controls on all automatic or remotely -controlled
gate operators.

10. The operator is intended for installation only on gates used

for  vehicles.  Pedestrians  must  be  supplied  with  a  separate
access  opening.  The  pedestrian  access  opening  shall  be
designed  to  promote  pedestrian  usage.  Locate  the  gates
such  that  persons  will  not  come  into  contact  with  the
vehicular  gate  during  the  entire  path  of  travel  of  the
vehicular gate.

Содержание SL-1000 R

Страница 1: ...1 SL 1000 R RESIDENTIAL LIGHT COMMERCIAL SLIDE GATE OPERATOR MADE IN U S A ROTARY GATE SYSTEMS INC ALL RIGHTS RESERVED 2008 REV 1 1 1 877 331 4RGS 4747...

Страница 2: ...t reversing Sensor Easy troubleshooting with easy to interpret LED display 200 cycles per day when used on properly installed gates Input for non contact secondary entrapment protection device In addi...

Страница 3: ...t setup Stagger mode Stagger delay time Auxiliary relay mode Reverse delay time Low power mode Power failure mode Soft start stop duration Reset cycle count Maintenance alert trigger Mid travel stop p...

Страница 4: ...ecurity personnel Approved Obstruction Detection Devices The following contact or non contact obstruction detection devices have been approved for use with this slide gate operator as part of a UL325...

Страница 5: ...or installation A good earth ground is necessary to allow the controller s built in surge and lightning protection circuitry to work effectively All ROTARY GATE SYSTEMS gate operators are supplied wit...

Страница 6: ...ety devices have been included in the layout of the system o A separate pedestrian gate has been included in the gate layout in a location safe from contact with the vehicular gate when it is in the f...

Страница 7: ...7 Access Control Devices The SL 1000 R is compatible with any type of access control device which provides a dry contact relay for activation Installation Figure 2 Gate and Post Layout...

Страница 8: ...8 Figure 3...

Страница 9: ...st 7 Using a 5 16 drill drill a hole into the post through each of the four holes in the mounting plate Tap the holes using a 3 8 16 tap This step may be eliminated if welding the mounting plate to th...

Страница 10: ...ontrol panel Secure the operator motor wire so as to ensure that it will stay c lear of the pinion gear rack gear and gate panel when in motion If necessary the motor wires from the operator can be ad...

Страница 11: ...UT TERMINALS SINGLE INPUT TERMINALS PRIMARY SECONDARY COMM LINK TERMINALS FIRE DEPT INPUT TERMINALS ACCESSORY POWER TERMINALS DISPLAY PROGRAMMING BUTTONS INPUT POWER TERMINALS PLUG IN LOOP DETECTOR CO...

Страница 12: ...OR CURRENT HAS EXCEEDED THE OPEN CURRENT SETTING WHILE OPENING SET MAXIMUM OPEN CURRENT OPEN OBSTR MGT 2 SET OPEN OBSTRUCTION TERMINAL CONNECTED TO COMMON BY BEAM OR SAFETY EDGE OR SIGNAL FROM MGT OBS...

Страница 13: ...HEN STOP AGAIN AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED AND A RENEWED INPUT WILL BE REQUIRED TO START THE GATE AGAIN SHOULD THE GATE BE RESTARTED AND THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REAC...

Страница 14: ...CH PHOTOEYE FOR CLOSE OBSTRUCTION FIRE ACCESS SWITCH SOLENOID LOCK EXTERNAl POWER PHOTOEYE FOR OPEN OBSTRUCTION SINGLE CHANNEL RADIO RECEIVER MAGLOCK GATE EDGE SENSOR FOR REVERSE TWO CHANNEL RADIO REC...

Страница 15: ...T 110 VAC 110 VAC WIRES ARE UNDER TRANSFORMER MOTOR Connect motor wires from SL 1000 R gate operator LIMIT SWITCHES Connect to the wires from the limit switches Black wires go to COMMON RED to OPEN or...

Страница 16: ...f the gate For left hand installations program the controller for left hand operation WHEN CHANGING TO LEFT HAND OPERATION YOU MUST ALSO REVERSE THE MOTOR LEADS IN ADDITION Dual Gate Enable The factor...

Страница 17: ...If the close current load exceeds the programmed maximum load number the operator will stop reverse a short distance then stop again If after restart the overload or a close obstacle happens again be...

Страница 18: ...o ne operator for delayed opening and the other operator for delayed closing The Stagger Delay Time programming function see below sets the length of the delay NOTE This function will only be displaye...

Страница 19: ...is set for Open Immediate alternately the controller can be set for Fail Secure Open Immediate or Close Immediate Fail Safe If the AC power fails and the battery voltage drops below 17 volts 5 second...

Страница 20: ...med to open for 1 to 99 seconds the stop before reaching the open limit When a Mid travel stop position time has been programmed the gate will still fully open if the Fire Department input is triggere...

Страница 21: ...s function will not erase radio transmitters Transmitters must be deleted with the two functions above DO NOT RESET CONTROLLER WITHOUT CONSULTING TECHNICAL SUPPORT AT 877 331 4747 FUNCTION CL ENTER WH...

Страница 22: ...osing at any time Single Input Opens the gate if it s closed and closes th e gate if it s open open close programming option Activating the input while the gate is moving will reverse the gate Can be...

Страница 23: ...run alarm will beep twice as fast and continue for five minutes after the gate stops The sounder will chirp every five seconds when the gate is idle Correct the trouble close case replace battery or...

Страница 24: ...ndicated by EN 04 on the APeX display To clear this error press the RESET button on the out side of the control box and give the system an OPEN or CLOSE signal Model SL 1000 R Maintenance Battery Main...

Страница 25: ...in your area THIS WARRANTY APPLIES ONLY TO THIS PRODUCT WHEN INSTALLED BY A QUALIFIED DEALER AND NOT TO ANY ACCESSORIES THE GATE PANEL ITSELF OR ANY GATE SUPPORT HARDWARE THIS WAR RANTY ONLY COVERS TH...

Отзывы: