2
0706-04
3.3
Wiring
The AY-x25B is supplied with a 6-conductor 56-cm (22-in.) pigtail
with exposed wires coated with solder.
To connect the reader to the controller:
1.
Select the appropriate connections according to Table 1.
Table 1: Wiring
Wire Color
Function
Red
VIN 5–16 VDC
Black
Shield / Ground
Green
Data 0 / Data
White
Data 1 / Clock
Brown
Green LED CTL
Purple
Tamper Output
2.
Prepare the controller cable by cutting its jacket back 3 cm (1¼")
and strip the insulation from the wires about 1.2 cm (½").
3.
Splice the reader’s pigtail wires to the corresponding controller
wires and cover each joint with insulating tape.
4.
If the tamper output is being utilized, connect the purple wire to
the correct input on the controller.
5.
Trim and cover all unused conductors.
•
When using a separate power supply for the reader, this supply
and that of the controller must have a common ground.
•
The reader’s cable shield wire should be preferably attached to
an earth ground, or a signal ground connection at the panel, or
power supply end of the cable. This configuration is best for
shielding the reader cable from external interference.
3.4
Operation Instructions
Once the reader is wired to a power supply and to the controller, you
should test the reader.
To test the reader:
1.
Power up the reader.
Upon power up, the reader flashes and beeps once during Self-
Test. The LED then turns red indicating the readers has entered
Standby mode.
2.
Apply a MIFARE Classic EV1 credential to the reader.
The reader flashes and beeps once indicating the card has been
read successfully.
Declaration of Conformity
FCC ID = GCD-AYX25B
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the
Quick Links section on the ROSSLARE website at
Rosslare considers any use of this product as agreement to the
Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc.
Southlake, TX, USA
Toll Free: +1-866-632-1101
Local:
+1-817-305-0006
Fax:
+1-817-305-0069
Europe
Rosslare Israel Ltd.
22 Ha'Melacha St., P.O.B. 11407
Rosh HaAyin, Israel
Tel: +972-3-938-6838
Fax: +972-3-938-6830
China
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86-755-8610-6842
Fax: +86-755-8610-6101
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852-2795-5630
Fax: +852-2795-1508
Latin America
Rosslare Latin America
Buenos Aires, Argentina
India
Rosslare Electronics India Pvt Ltd.
Tel/Fax: +91-20-40147830
Mobile: +91-9975768824
CERT
ISO 9001
ISO 14001