Introduction 

The MD-IO84B is an optional I/O expansion board for use with Rosslare’s 

AC-225x-B and AC425x-B series of networked access control panels. 
 
This expansion board adds an additional four relay outputs and eight 
supervised inputs to the access control panel. 
 
The host access controller has complete control over the additional inputs 
and outputs of the MD-IO84B expansion board. The inputs and outputs 

can be configured using an access control software system such as 
Rosslare AxTraxNG™. The software system also configures the MD-IO84B's 
input connection topology. 
 

Once connected to the system, these IO devices can allow you to scale and 
expand your system and by using AxTraxNG™ management you can 
program extended access control features, adding more automation 
capability to the your system. 

 
This guide explains how to install and begin working with your new MD-
IO84B access controller expansion board.  

Figure 1: MD-IO84B 

 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics 

Input Voltage 

12 VDC 

Input Current 
(not including attached devices)) 

Standby: 30 mA 
Maximum: 135 mA 

Number of Inputs 

Number of Outputs 

Output Relays 

5

 

A with N.O., N.C., and COM contacts Form-

C relays 

Inputs Voltage 

5 VDC maximum voltage 

2.2

 

Input Characteristics 

Input Type: 

Selectable as: 

 

Normally Open 

 

Normally Closed 

 

Non-supervised (2 states) 

 

Supervised with one resistor (3 states) 

 

Supervised with two resistors (4 states) 

2.3

 

Physical Characteristics 

Dimensions (L x W x D) 

100 x 75.9 x 32.5 mm (3.9 x 3.0 x 1.3 in.) 

Weight: 

98.2 g (3.5 oz) 

2.4

 

LED Indicators 

Power LED: 

Active when connected to a power source 

Output LEDs: 

Four LEDs 
Each output LED is active when an output relay is 
energized and N.O. to COM contacts are shorted. 

3.

 

Attaching the MD-IO84B 

To attach the MD-IO84B: 

1.

 

Disconnect power to the access control panel before attaching the 
MD-IO84B. 

2.

 

Remove the MD-IO84B cover by lightly pulling one of the cover knobs 
away from the circuit board. The entire cover comes away from the 
board. 

3.

 

Peel off the label on the cover of the panel marked "Remove to install 
I/O board".  

 

The label is located on the same side of the panel as the DIP switch. 

4.

 

Insert the 10-pin male connector of the MD-D02B into the gap in the 
panel cover labeled "IO EXPANSION SLOT". 

 

The text on the MD-D02B must face the same way as the text on the 
panel cover. 

5.

 

Tighten the screws securing the cover to the access control panel, and 
the four Philips screws on the MD-D04B circuit board. 

6.

 

Replace the cover on the expansion board, using it as a guide to ease 
the MD-D04B into the panel's 10-pin female connector. 