background image

 

4.

 

Wiring 

The AY-x12C is supplied with a 10-conductor 18” pigtail. 
To connect the reader to the controller: 
1.

 

Prepare the reader cable by cutting its jacket back about 3 cm 

(1¼") and strip the insulation from the wires about 1.2 cm (½"). 

2.

 

Prepare the controller cable by cutting its jacket back 3 cm (1¼") 

and strip the insulation from the wires about 1.2 cm (½"). 

3.

 

Splice the reader’s pigtail wires to the corresponding controller 

wires (as indicated in Table 1) and cover each joint with insulating 

tape. 

4.

 

If the tamper output is being utilized, connect the purple wire to 

the correct input on the controller. 

5.

 

Trim and cover all unused conductors. 

 

 

When using a separate power supply for the reader, this supply 
and that of the controller must have a common ground. 

 

The reader’s cable shield wire should be preferably attached to an 
earth ground, or a signal ground connection at the panel, or 
power supply end of the cable. This configuration is best for 

shielding the reader cable from external interference. 

Table 1: Wiring 

Wire Color 

Function 

Red 

5–16 VDC 

Black 

Ground 

Green 

Data 0 / Data 

White 

Data 1 / Clock 

Orange 

Green LED 

Brown 

Red LED 

Purple 

Tamper 

Yellow 

Buzzer 

Blue 

Hold 

Grey 

Data Output Mode 

 

 

5.

 

Operation Instructions 

5.1

 

Testing 

Once the reader is wired to a power supply and to the controller, you 

should test the reader. 
To test the reader: 
1.

 

Power up the reader. 
Upon power up, the reader flashes and beeps once during Self-

Test. The LED then turns red indicating the readers has entered 
Standby mode. 

2.

 

Apply a PROX card to the reader. 
The reader flashes and beeps once indicating the card has been 
read successfully. 

5.2

 

Data Output Mode Line 

The Data Output Mode Line is used to select whether the reader 

outputs in Wiegand 26-Bit or Clock & Data format. 
When the Mode Line is open, the reader outputs Wiegand 26-Bit. 
When the Mode Line is pulled to ground, the reader outputs Clock & 

Data. 

5.3

 

LED Control 

The reader has a bi-color (green/red) LED and two LED control lines, 

one for green LED control (orange wire) and the other for the red LED 

control (brown wire). 
When both LED control lines are open, the reader self manages the 

LED behavior. In Standby mode, the LED remains red. When a card is 
presented, the LED flashes green and then returns to red. 
When a LED control line is pulled to ground, the LED changes to the 

related LED color and the self-management is disabled.  If both LED 
control lines are pulled to ground, the LED is amber colored. 

5.4

 

Buzzer Control 

When the Buzzer control line (yellow wire) is open, the reader self 

manages the buzzer behavior and beeps when a card is read 

successfully. When the Buzzer control line is pulled to ground, the 
buzzer sounds. 

5.5

 

Hold Control 

When the Hold control line (blue wire) is open, the reader functions 

normally. When the Hold line is pulled to ground, the hold function is 

activated. When active and a card is read, no card data is sent on the 
Wiegand lines; however, the reader continues to buffer the last card ID 

read and sends that ID data when the Hold line is released. 

Отзывы: