Rosslare AC-S73 Скачать руководство пользователя страница 1

 

Instruction Manual 

1

2

5

6

7

8

9

0

#

3

4

 

AC-S73 

Secured Access Control Unit 

 

04/02

 

AC-S73

 Page 

04/02

 

Contents 

Introduction....................................................... 5

 

Technical Specifications................................. 7

 

Key Features.................................................. 8

 

Installation ...................................................... 10

 

Mounting the AC-S73 Controller .................. 10

 

Wiring the AC-S73 ....................................... 11

 

Wiring Diagram ............................................ 13

 

Features and Concepts 

Normal, Secure, & Master Users.................. 14

 

Modes of Operation...................................... 16

 

Changing the Modes of Operation ............... 18

 

Request to Exit (REX) Function ................... 20

 

Case and Back Tamper ............................... 21

 

PC-15T Power Supply Unit .......................... 22

 

Programming the AC-S73 .............................. 23

 

Entering Programming Mode ....................... 25 
Exiting Programming Mode .......................... 26 
Changing Lock Strike Code 1....................... 27 
Changing Lock Strike Code 2....................... 29

 

Changing the Programming Code................ 31

 

Changing the Normal / Secure Code ........... 32

 

Changing the Normal / Bypass Code ........... 33

 

Setting Fail Safe/Secure Operation.............. 34

 

Setting the Lock Strike Release Time .......... 34

 

Enrolling Primary & Secondary Codes ......... 36

 

AC-S73

 Page 

04/02

 

Deleting Primary & Secondary Codes.......... 41

 

Return to Factory Default Settings ............... 44

 

Replacing a Lost Programming Code .......... 45

 

Replacing a Lost Normal / Secure Code...... 46

 

PC-15T / PS-A15T/ PS-B15T / PS-E15T / PS-
F15T POWER SUPPLY INSTALLATION 
INSTRUCTIONS ...............................................47

 

INTRODUCTION & KEY FEATURES.......... 47

 

PS-15T WITH ENCLOSURES..................... 51

 

Glossary...........................................................55

 

Limited Lifetime Warranty ..............................60

 

Technical Support...........................................63

 

AC-S73

 Page 

04/02

 

Introduction 

The AC-S73 is a vandal resistant keypad access 
control unit suitable for external applications. 
The unit accepts up to 500 users and provides 
entry via the use of PIN codes. 
It is designed for high security applications, due 
to the fact that lock strike output and Request to 
Exit input are not located directly on the AC-S73, 
which eliminates the possibility of unauthorized 
entry to the restricted area. A specific Power 
Supply Unit, PC-15T, must be used in 
conjunction with the AC-S73. See page 47 for a 
detailed description of the PC-15T. 

Equipment Provided 

The following is provided as part of every  
AC-S73 package: 

• 

AC-S73 Access Control Unit. 

• 

Installation Kit 

• 

Installation and Operating Instructions 

AC-S73

 Page 

04/02

 

Additional Equipment Required 

Secured Power Supply PC-15T which connects 
to the following items: 

1)  Electric Lock Strike mechanism, which 

implements Fail Safe (Power to Lock) or 
Fail Secure (Power to Open) functions. 

2)  Request to Exit (REX) button 

Normally open type. Switch is closed when 
pressed. 

PC-15T provides bell function. 
Other Rosslare accessories can be found at 
Rosslare's 

Web Site: 

http://www.rosslare.com.hk

 

AC-S73

 Page 

04/02

 

Technical Specifications 

Electrical Characteristics 

Operating Voltage Range:

 

12V DC 

Provided from Secure Power 
Supply (PC-15T) 

Maximum Input Current:

 

Standby: 
Maximum:  

15mA 
92mA 

LEDs

 

Two Tri-colored LEDs 

Communication 

C1, C2

 

Open collector 5V terminated

 

Environmental Characteristics 

Operating 
Temperature:

 

-25°F to 145°F (-31°C to 
63°C) 

Operating 
Humidity:

 

0 to 95% (Non-
Condensing) 
Suitable for outdoor use. 
(IP 65)

 

Mechanical Characteristics 

Dimensions: 

5.91"(150mm)L x 
1.65"(42mm)W x 
1"(27mm)D

 

Weight: 

0.9 lbs (400g)

 

AC-S73

 Page 

04/02

 

Key Features 

Here are some of the AC-S73’s key features: 

• 

Bi-directional communication with PC-15T 

• 

Built in piezoelectric keypad for PIN code 
entry 

• 

Internal Buzzer 

• 

Comes with security screw and security 
screw tool 

• 

Two Status / Programming Interface LED's 

• 

Three User Levels 

 

Normal

 User 

 

Secure User 

 

Master 

User

 

• 

Three Modes of Operation 

 

Normal Mode 

 

Bypass Mode 

 

Secure Mode 

• 

"Code Search" feature that helps make 
maintaining user codes easier. 

• 

Request to Exit (REX) signal from PC-15T 

  Comes with mounting template for easier 

installation. 

  Built in Case and Back Tamper 

• 

Bell feature is available with PC-15T.

 

• 

Programmable Lock Strike Release Time 

AC-S73

 Page 

04/02

 

2

 x 6 M

a

tr

ix

 K

ey

p

ad

Ca

s

e S

c

re

w

1

2

5

6

78

90

#

3

4

Door

 LE

D

M

ode

 LE

D

Be

ll

 B

u

tt

o

n

 

AC-S73

 Page 

10 

04/02

 

Installation 

Mounting the AC-S73 Controller 

1)  Before starting, select the location to mount 

the AC-S73 controller. This location should 
be at shoulder height. 

2)  Drill holes into the back of the metal 

according to how you want to mount the 
AC-S73. For US Gang Box installation 
there are two hole indicators on the back of 
the metal cover specifically aligned for the 
US Gang Box. (Shown marked as ”A” in 
diagram below). 

A

A

CAUTION!

DO NOT DRILL

This is the Tamper Lens

 

3)  Screw the AC-S73 back cover to its 

mounting location. 

4)  Wire the controller according the wiring 

instructions on the following page. 

5)  Return the front cover of the AC-S73 to the 

mounted back plate. 

AC-S73

 Page 

11 

04/02

 

6)  Secure the front cover by using the 

supplied security screw in the Installation 
Kit. An L-Shaped tool is provided for use 
when tightening the security screw. 

Wiring the AC-S73

  

The controller is supplied with a 16-inch pigtail, 
having a 4-conductor cable. To wire the 
Controller, perform the following steps: 

1)  Prepare the controller cable by cutting the 

cable jacket back 1¼ inch and strip the wire 
½ inch. 

2) 

Splice the controller pigtail wires to the 
corresponding devices and cover each 
connection. Refer to the wire color guide 
provided below and to the wiring diagrams 
provided on the following pages.

 

Wire Color Guide 

Color Description 

RED

 V 

INPUT 

BLACK

 GROUND 

WHITE 

 C1 

GREEN

 C2 

3) 

Trim and cover all conductors that are not 
used.

 

AC-S73

 Page 

12 

04/02

 

A typical wiring diagram is shown on the next 
page; for other wiring diagram examples refer to 
the support section of the Rosslare Web Site. 

http://www.rosslare.com.hk/support

 

AC-S73

 Page 

13 

04/02

 

Wiring Diagram 

Wiring diagram and schematic for the AC-S73. 

+V

C1

C2

SECURED  CONTROLLER

N.C.

N.O.

REX.

LOCK 12VDC

VI

N

+

B

A

T

16

V

A

C

12

V

D

C

ROSSLARE

PC-15T

SPEAKER OUT

OUTPUT LED

O

P

-P

S

A

12

-V

4

16V AC (1.5A, 25VA)

Not provided in 

PS-E15T and PS-F15T

12V LEAD ACID

BATTERY

UP TO 7 AH

RECOMMENDED

AC-S73

+V

C1

C2

N.

C.

N.O

.

FROM A TRANSFORMER

(12 VDC @ 300mA)

AC Mains

(Black)

(

)

White

(

)

Green

(Red)

 

AC-S73

 Page 

14 

04/02

 

Normal, Secure, & Master Users 

The AC-S73 accepts up to 500 users and 
provides entry via the use of PIN codes. Each 
user is provided with two code memory slots, 
Memory Slot 1 (Primary Code) and Memory Slot 
2 (Secondary Code). 
The way in which the two memory slots are 
programmed determines a user’s access level 
and also determines the way in which the  
AC-S73 grants access in its three modes of 
operation. 

There are three user levels: 

Normal User 

A Normal User only has a Primary Code and is 
only granted access when the AC-S73 is in 
Normal or Bypass Mode. 

Secure User 

A Secure User must have a Primary and 
Secondary Code programmed; the two codes 
must not be the same. The Secure User can 
gain access when the AC-S73 is in any of its 
three modes of operation. In Normal Mode the 
Secure User must use their Primary Code to 
gain entry. In Secure Mode the Secure User 
must present both their Primary and 
Secondary Codes in order to gain entry. 

AC-S73

 Page 

15 

04/02

 

Master User 

A Master User must have both Primary and 
Secondary Codes programmed with the same 
PIN code. The Master User can gain access 
during any mode of operation by presenting 
their PIN code to the controller. (The Master 
User is convenient but is less secure than a 
Secure User.) 

 

AC-S73

 Page 

16 

04/02

 

Modes of Operation 

The AC-S73 has three modes of operation: 

1) Normal 

Mode 

• 

MODE LED is 
green 

Mode

Door

GREEN

 

Normal Mode is the default mode. In Normal 
mode the door is locked until a Primary Code is 
presented to the controller. Special codes such 
as 

Lock Strike Code 1

 and 

Lock Strike Code 

2

 are active in Normal mode. (See pages 27-29 

for more information on the Lock Strike Codes). 

2) Bypass 

Mode 

• 

MODE LED is 
orange 

Mode

Door

ORANGE

 

In Bypass Mode, access to the premises is 
dependent on whether the controller's Lock 
Strike Relay is programmed for Fail Safe 
Operation or Fail Secure Operation. 
When the Lock Strike is programmed for Fail 
Secure Operation, the door is locked until the 
doorbell button is pressed. 
When the Lock Strike is programmed for Fail 
Safe Operation, the door is constantly unlocked. 

Содержание AC-S73

Страница 1: ...ler This location should be at shoulder height 2 Drill holes into the back of the metal according to how you want to mount the AC S73 For US Gang Box installation there are two hole indicators on the back of the metal cover specifically aligned for the US Gang Box Shown marked as A in diagram below A A CAUTION DO NOT DRILL This is the Tamper Lens 3 Screw the AC S73 back cover to its mounting locat...

Страница 2: ...ed These settings are the called the Default Factory Settings The table below shows the names of all the AC S73 Menus It also shows of all the AC S73 s default factory codes and settings AC S73 Page 24 04 02 Programming Menu Factory Settings Menu Description Menu Number 2580 Changing Lock Strike Code 1 1 0852 Changing Lock Strike Code 2 2 1234 Changing Program Code 3 3838 Changing Normal Secure Co...

Страница 3: ...hod When deleting a User Slot both the Primary Code and the Secondary code are erased Deleting Primary and Secondary Codes using the Standard Method 1 Enter Programming Mode Mode Door GREEN 2 Press 8 to enter Menu 8 The Mode LED will turn red Mode Door RED ORANGE 3 Enter the 3 digit User Slot codes you wish to delete The Mode LED will flash red Indicating the controller is waiting for the Programm...

Страница 4: ... providing an Open Circuit or Closed Circuit output to external devices REX An abbreviation of Request To Exit Request To Exit REX Refers to a button that can release the door from inside Commonly located at the reception desk or near a door as an emergency door release S Secondary Code An additional code issued to enable access in Secured Mode Users with non identical Primary and Secondary Codes ...

Страница 5: ... www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk www rosslare com hk...

Отзывы: