¡Error! Utilice la ficha Inicio para aplicar Heading 1 al texto que desea que
aparezca aquí.
AC-425 Hardware Installation and User Guide
21
4.
Input and Output Connections
This chapter describes the AC-425 access control panel's input and output connections.
4.1
Input Types
There are four input types:
N.C.
N.O.
Single EOL resistor
Double EOL resistor
Inputs IN1, IN2, IN3, and IN4 may be configured individually as either supervised or non-
supervised inputs. Tse the AxSraxNG™ system to configure each input separately.
Non-supervised inputs have two states:
Normal
Abnormal
Supervised inputs have three states:
Normal
Abnormal
Trouble
The Trouble state is caused by either tampering with the input circuit or by faulty hardware
installation. Once an input is configured as a supervised input, add a resistor of 2.2 k
Ω
, of
8.2 k
Ω
, or both on the input circuit. See the following diagrams.
4.1.1
Normally Open Input Connection
A Normally Open Input has 2 states:
Switch Open – Normal State:
Loop resistance = Infinite (open circuit)
Switch Closed – Abnormal State:
Loop resistance = 0 (short circuit)