background image

KXGHT

 

FUNCTION

 

 

FAIL SAFE

 

 

 Characteristics

 

 

-

 

Automatic source 90V - 240V ~ ac 

 

-

 

Motor with maximum power 

1200W

 

-

 

HALL sensor limit switch and Reed Switch 

-

 

Internal memory for 1024 removable buttons 

-

 

HCS reception system, anti-cloning 

-

 

433 Mhz reception frequency 

-

 

Residential and building function 

-

 

electronic clutch 

-

 

Delete individual passkey code 

-

 

Output for traffic light / garage light 

-

 

Input for closing photocell 

-

 

Lock output 

-

 

Adjustable automatic closing 

-

 

Opening and closing button 

-

 

Independent closing button 

-

 

Pass and close function (with photocell) 

-

 

Physical and virtual encoder 

-

 

Automatic route recognition 

-

 

Compatible with KXHI 1024 control panel 

and all Rossi operators 

  

Electronic board installation manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Layout and Components

 

  

N - Neutral/Phase 2

 

 

F - Phase (Power Mains Input 90~240VAC)

 

CAP - Permanent Capacitor

 

U/V/W - Motor Wires (U = Core, yellow wire)

 

--------------------------------------------------------------------------------------------------------

 

12V - 12.8VDC -300mA output (for ROSSI accessories)

 

GND - Core for 12V Output and Accessories

 

FCH - Lock board Output

 

PHOTOCELL – Closing Photocell Input – RX TX(-) – FS Photocell 

Negative SIN LIGHT – Signal Light / Garage Light

 

FA -  Opening limit switch

 

CM - Core for button and limit switch

 

FF -Closing limit switch

 

BOT_A – Opening / Closing Button

 

BOT_F – Closing Button

 

GND - Core Pushbutton and Coaxial Cable Mesh for External Antenna ANT - 

Coaxial Cable Core for External Antenna / Internal Antenna Wire

 

 

ADJUSTMENTS - Functional Adjustment Button / Path recognition and brake 

levels

 

 

 LEARN - Learn / Erase Remote Controls Button

 

--------------------------------------------------------------------------------------------------------------

 

ST - Event Indicator LED

 

FA - Green Led Open Gate Indicator

 

FF – Red Led Gate Closed Indicator 

-------------------------------------------------------------------------------------------------------------- 

DIP-1 F.SAFE – Fail Safe Function Enabled = ON / Disabled = OFF 

DIP-2 ENC / Ñ - With encoder = OFF / Without encoder = ON 

 

DIP-3 LV-PS - Light Gate = OFF / Heavy Gate =ON 

DIP-4 LOCK – Lock/Latch Enabled = ON / Disabled = OFF DIP-5 PAUSE – 

Automatic Closing Enabled = ON / Disabled = OFF DIP-6 BUILDING – Building 

Function Enabled = ON / Residential Function = OFF

 

------------------------------------------------------------------------------------------------------------- 

J9 – ENCODER 

Installation

 

  

 

 

  

N/F - Input 90~240VAC

 

 

Voltage input already intercepted by a 10A bipolar circuit 

breaker and grounded equipment. 

 

CAP- 

Permanent Capacitor

 

 

Capacitor according to motor power, wires do not have 

polarity.

 

       

 

  

U - V - W - Motor Wires

 

 

Note: Motor with maximum power of up to 1200W

 

The motor has 3 wires. The core (check the label on the 

motor) normally the yellow one must be connected to output 

U. Outputs V and W determine the direction of rotation of the 

motor (right - left).

 

To perform this test, leave the gate in the middle of the course 

(away from the limit switches) and activate, the FF or FA LED 

will flash indicating the closing or opening rotation direction. 

 

 

 

 

Limit switches: 

The control unit automatically understands the two limit switches systems, by contact (reed) and/or hall without the need for programming. 

 

NOTE: you must always use the magnet for the hall sensor; if you want to deactivate the hall sensor press 12x the 

adjustment button Reed Limits CM-FA-FF

 

Randomly choose one end of each wire of each limit switch and one forming a core.

 

The other two ends that will be FF (closed) and FA (open). Connect the wires to the respective terminals FF, FA and CM (core).

 

Observe the position of the limit switches on the actuator so that when the gate is closed, the red LED FF lights up, and when open the green LED 

FA lights up.

 

Hall sensor limit switch

 

 

The hall sensor identifies the polarity of the magnets, north and south. Before attaching the magnets, identify the FA and FF, to do this move the magnet over 

the rack

 

until passing in front of the hall sensor, which will turn on the green FA or red FF LED. (If the two magnets light the same LED, invert the magnet position

 

 

which does not match the chosen Open or Closed side.)

 

SIN -GND 

- Signal light consists of interconnecting a compatible light with the gate control panel using the SIN and GND terminals.

 

 

-GND LIGHT 

- Garage light. to interconnect the Garage LIGHT accessory board, using the LIGHT and GND terminals.

 

  

 

 

 

BOT / GND, 

The Opening and Closing Pushbutton consists of installing a pulse button (bell type) on the terminal (BOT) of the control unit, 

interconnecting

 

a receiver or an external command system.

 

 

BOT_F/GND

, The Closing Pushbutton consists of installing a pulse button (bell type) on the terminal (BOT_F) of the control unit or interconnecting 

a

 

receiver or an external command system. The unique function of closing the gate is activated after pressing and 

releasing

 the button.

 

 

Note

: The Button is used for manual activation in watchtowers, activation through the intercom or any need for remote activation

 

by an external button.

 

With SETTING at 9X (default function), BOT works as "open-to-close" and BOT_F only stops and closes after releasing the BOT _F button.

 

With the SETTING at 10X, BOT A only opens and BOT_F only closes after releasing the button.

 

 

 

 

 

 

 

up t

 

 

Co

ax

ia

 

 

 

 

 
 

 

switchboard antenna

 

 

         16cm

 

 

 

GND/ANT

 

 

Frequency reception antenna, connect the stripped part of the 16cm wire to the ANT terminal. 

If you need a longer range, connect a 2m coaxial cable to the antenna input. - At the top of the 

cable you should uncover the 16cm core.

 

 

In the connection part with the switch you must place the core in the ANT terminal and the 

mesh in the GND, as in the control panel diagram.

 

 

Pg. 4

 

Core 

Mesh 

16 cm from the core 

without mesh 