
3.
Select ME 1 and s source on the background
bus of ME 2. Notice that ME 1 is not being
used as the background of ME 2.
Configurable Program Outputs (MultiFeed)
Each ME can have multiple program and
preview outputs that can be configured to
include only select keys or replace the
background and preset buses with the utility
buses.
Figure 3: Configurable Program Output Example
Including or excluding a key from a program
output does not change the on-air status of the
key, only whether the key is included in a
particular output when the key is on-air. The
key must still be transitioned on or off-air from
the transitions area.
To Configure a Program Output
1.
Press the
SEL
button for the ME that you
want to configure an output for and press
Program Assignment
.
2.
Select the keys that you want included in
each output for the ME.
Note:
The output must be set to FlexiMode from the
Installation menu or the key selection buttons will be gray.
3.
Select the buses to use for the background
of each output.
•
Bkgd/Pst
— sources selected on the
background and preset buses of the ME
are used.
•
U1/U2
— sources selected on utility bus
1 and utility bus 2 of the ME are used.
Switcher Reset and Shutdown
The entire switcher or just an ME can be
restarted or reset from the control panel. This
is useful if they switcher is in an unfamiliar
state, or you are troubleshooting an issue.
• Switcher Shutdown — closes the switcher
application and prepares the control panel
and frame to be powered off.
• Switcher Restart — physically powers down
the frame and re-starts it
• ME Reset (ALL+ALL) — defaults the state of
an ME, or all MEs
To Shutdown the Switcher
1.
Press
HOME
>
More
>
System Shutdown
.
2.
Press
Shut Down
.
The switcher will prompt you to confirm the
restart. Once confirmed, the switcher
powers down.
3.
Toggle the power switches in the frame and
control panel to Off.
Refer to the QuickStart poster that came
with your switcher for the locations of
power switches in control panel and frame.
To Restart the Switcher
Note:
The control panel will not start up properly if there is a
USB drive in the USB port on the control panel. You must remove
the USB drive from the USB port on the control panel before
powering the control panel up.
1.
Press
HOME
>
More
>
System Shutdown
.
2.
Press
Restart
.
The switcher will prompt you to confirm the
restart. Once confirmed, the frame and
control panels will power down and boot
up again.
ME Reset (ALL+ALL)
Each ME can be reset to return it to the default
state. The ME can be reset from the Global
Memory module, or the Effects Memory module.
Ultrix Acuity Operation Manual (v10.1) — Switcher Basics • 29
Содержание Ultrix Acuity
Страница 1: ...Ultrix Acuity Operation Manual v10 1...