Editing a Macro using the Panel
You can add extra button sequences to an existing macro or you can join two existing macros together.
To add to a macro using the panel
1. On the RCP-ME, hold the
Macro
#x
button until the button begins to flash rapidly.
2. Release the button.
The button flashes slowly, indicating that the RCP-ME is now ready to record a macro.
3. Hold the
Macro
#x
button again.
The selected macro is played back internally and is then ready to receive the additional button sequences.
4. Do one of the following:
• To add an extra button sequence, press the required buttons to add to the macro in the correct sequence until
your task is completed.
• To add an existing macro, press the button for the macro you want to add.
Each button acknowledges that it has been pressed by flashing briefly.
5. Press the
Macro
#x
button again to end the recording process.
The existing macro is overwritten with the new macro.
Configuring a Macro using DashBoard
Macros can be configured in DashBoard using the
Macro Events
tab.
To configure a macro using DashBoard
1. Assign a macro to a button (see “
2. Open the RCP-ME Panel Config interface (see “
To open the RCP-ME Panel Config interface
3. Select the
Macro Events
tab.
4. In the
Num. Rows.
box of the macro you want to configure, enter or select the number of events to be assigned.
5. Click
Update
to add the events to the
Event
column of the macro.
6. In the
Function
column, use the list to select the function to perform for the event. The options are as follows:
•
Switch
— performs a standard crosspoint switch.
•
Macro
— performs a macro within the executed macro. The
Output
column is the macro number and the
other columns have no effect.
•
Protect
— creates a protect condition on the destination of the selected crosspoint (see “
protect/lock button using DashBoard
” on page 61). The
Output
column is the output number, the
Input
column is the protect status (0 = release the protect for the output, 1 = take protect for this output), and the
Level
column has no effect.
7. In the
Output
column, perform the following:
a. Click inside the
Output
table cell.
b. Enter a destination output number for the event.
8. In the
Input
column, perform the following:
a. Click inside the
Input
table cell.
b. Enter a source input number for the event.
9. In the
Level Mask
column, select the level mask(s) for the device affected by the macro. A selected router
level is indicated by a blue square.
Содержание Ultricore RCP-ME
Страница 1: ...RCP ME User Guide...
Страница 6: ......
Страница 10: ...iv Contents RCP ME User Guide v4 0...
Страница 14: ...14 Introduction RCP ME User Guide v4 0...
Страница 28: ...28 Getting Started RCP ME User Guide v4 0...
Страница 54: ...54 Macros RCP ME User Guide v4 0...
Страница 56: ...56 Salvos RCP ME User Guide v4 0...
Страница 60: ...60 Category Index Mode RCP ME User Guide v4 0...
Страница 70: ...70 Linking Remote Control Panels RCP ME User Guide v4 0...
Страница 72: ...72 Cutbus Mode RCP ME User Guide v4 0...
Страница 76: ...76 Managing Panel Configurations RCP ME User Guide v4 0...
Страница 80: ...80 Monitoring RCP ME User Guide v4 0...
Страница 94: ...94 DashBoard Interface Overview RCP ME User Guide v4 0...
Страница 96: ...17 96 RCP ME Hexadecimal to Router Level Conversion RCP ME User Guide v4 0...