Encoder Configuration • 3–9
Stream Setup Area
The
Stream Setup
area allows you to select a module and configure it by attaching a data source
to the module.
Under the
Module
heading is a column of boxes in which the different modules available on the
encoder can be selected. The example menu shows a Closed Caption module being used for
stream 1, a Transparent module being used for stream 2, a Constant Data module being used for
stream 3, and a Bridging module being used for stream 4.
The column of boxes under the heading '
Data Source
', shows the data source that the selected
module is using. The example main menu shows that the Closed Caption module is connected to
PORT A.
The 'Module' boxes, depending on which modules have been purchased, can contain ‘Transparent
Module’, ‘Caption Module’, ‘Constant Data Module’, or ‘Bridging Module’.
The available data sources are: LAN Ports, Port A, Port B, Port C, Modem, and a file of constant
data.
To set up a stream, select the module you wish to configure from the
Module
box and click the
Configure
button for that stream. The
Stream Configuration
menu for the module selected is
displayed, allowing you to select the data source and other stream related parameters.
The
Clear Streams
button resets all streams for the selected program. All streams are lost if this
option is selected. The reset does not change any of the other parameters on the TES9Set main
menu.
Save and Exit Button
The
Save
and
Exit
button saves the current changes in non-volatile storage in the encoder and
then exits. When this command is selected, the configuration information is sent to the TES9; the
STATUS 1
LED then starts blinking alternately yellow and red while the configuration is being
saved, and finally turns green again. The saving progress is monitored in a window of the
software.
Cancel Button
The
Cancel
button discards the changes and takes the TES9 out of setup mode.
Load Factory Defaults Button
The
Load Factory Defaults
button restores the TES9 to its factory settings, with the exception
that the LAN Address, Netmask, Gateway, and DHCP settings are not changed. This will erase
any settings that have been made.
Caution
— It is important to avoid powering down the encoder while the STATUS 1 LED
is blinking yellow and red, as doing so could cause the encoder's configuration and
software to be lost, requiring it to be re-loaded by Ross Video. After selecting the Save and
Exit command, you should ensure that you do not power down the encoder until the
STATUS 1 LED stops blinking yellow and red.
Содержание TES9
Страница 1: ...TES9 Multi Function HD SD SDI VANC Processor Software User Manual ...
Страница 6: ......
Страница 14: ...1 6 Introduction TES9 Software User Manual Iss 04 ...
Страница 26: ...3 10 Encoder Configuration TES9 Software User Manual Iss 04 ...
Страница 67: ...Notes ...