Synergy Q/MD Engineering Manual (v9.1 MD)
Completing Setup • 12–3
•
Installation Registers
This category stores and recalls all setup and configuration settings. The following data
is contained in the file:
•
3D Sequence Registers
This category stores and recalls all Squeeze & Tease MD Sequence registers.
•
Bus Map Registers
This category stores and recalls all 17 of the Bus Maps used to assign video sources to
crosspoint buttons. There are 16 user defined bus maps, and a single default bus map.
•
All Individual Memories Registers
This category stores switcher memories individually to their own separate files.
The file storage and recall system is accessible via the
Disk Menu
. This menu provides complete
flexibility with regard to registers. You can independently store or recall individual categories as
desired (without affecting other files), or you can store
all categories
at once.
Even though all the data listed above is stored in the non-volatile “flash” memory of the switcher, it is
always wise to keep an archive or “engineering” backup on hand that contains your important setups
and configurations. Not only does this provide security in case you need to re-program the Synergy
Q/MD switcher, but it also allows you to have a variety of switcher
files
available (on multiple USB
Drives or Hard Drive Setups), should you need to load
different
configurations — for different clients
or different production situations. Refer to the section “
Backing Up Setups to an External
” on page 6–19 for more information on backing up your switcher files.
• BNC Input Names
• Output Setup
• BNC Input Types
• Clean Feed Setup
• Tally Configuration
• GPI Input / Output Setup
• Alpha Setup
• Device Setup
• Auto Key Configuration
• Editor Communications Setup
• Panel Button Assignments
• Custom Banks
• Aux Bus Setup
• Custom Device Setup
Note
You
cannot
store or recall while a custom control function is playing.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...