Synergy Q/MD Engineering Manual (v9.1 MD)
Software Upgrades and Options • 6–29
•
The
HWRev
column lists the hardware revision number of each board and card in
the frame.
•
The
SWRev
column lists the revision number of the software that is currently
installed on each board or card in the frame.
•
The
BuildInfo
column lists the build, or software compile, date of the software that
is currently installed on each board or card in the frame.
This completes the procedure for displaying information on frame boards.
Installing Serial Numbers
If the label “
000000
” appears at the top of the
Installed Options Menus
, a serial number is required.
Use the following procedure to install a serial number:
1. Navigate to the
Installed Options Menu 1-2
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Installed Options
.
2. Press
Enter Serial Number
to display the
Serial Number Menu
.
Serial Number Menu
3. Call
Ross Video Technical Support
at the number listed on the menu.
4. When you speak to our Technical Support representative, tell them your name, your
facility name, and the
Encrypt Code
as listed on the menu.
5. You will be given a numeric code.
•
Enter the code using the keypad in the
Global Memory Area
of your switcher.
•
To complete the process, press
ENTER
on the keypad or press
Finished
on the
Serial Number Menu
.
This completes the procedure for entering the serial number.
Installing Software Options
Use the following procedure to activate your software options (after entering a new serial number) or
to install a new software option that you have just purchased.
1. Ensure that your serial number is properly entered.
Note
Note that an
Encrypt Code
is listed. The code is a
random number
that is generated each time the switcher is powered up. Its purpose is to
prevent unauthorized installation of software options. The code
remains valid until the switcher is powered down or reset. The next
time the switcher is powered up, a
new
Encrypt Code is generated.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...