Synergy Series Operation Guide (v18)
Switcher Basics • 4–23
Please note the following important rules:
•
There are four internally generated sources available:
~
BLACK
— normally placed on the first or left-most crosspoint in a bus row.
~
SHIFT
— typically placed as the last or right-most crosspoint in a bus row but can
be placed on any crosspoint.
~
COLOR BKGD
1
— typically placed as the third or second to last crosspoint in a
bus row.
~
COLOR BKGD
2
— typically placed as the second to last crosspoint in a bus row,
or as the
shifted
crosspoint for
COLOR BKGD
1
.
•
External sources can be
turned off
as part of switcher setup, or placed on
more than one
crosspoint. Refer to Chapter 6, “
BNC Configuration and Check
” in the
Synergy Series
Installation Guide
for details.
•
On each switcher, between the
PGM
and
PST
buses only, small crosspoint numbers are
silk-screened on the panel itself. These labels are printed in increments of five, and are
designed to assist your facility engineer with locating crosspoints particularly during
setup modes.
•
Selecting a crosspoint button assigned to a VTR device will enable you to enter a VTR
Clip ID or Number using the keypad in the
Global Memory Group
. Some devices
allow you to also enter the VTR Clip ID on the keypad. For those devices, you can
toggle between entering a
Clip ID
and a
Clip Number
by pressing the
VTR Clip
button. Refer to the section “
Clip Control Overview
” for more information.
•
If you enabled the
Look Ahead Serial Tally
option, crosspoint selections on the Key
Buses, including the DSK sources, will be delayed by the specified number of fields.
Refer to Chapter 7, “
Basic Communications Setup
” in the
Synergy Series Installation
Guide
for instructions on how to enable the
Look Ahead Serial Tally
option.
SHIFT Button
On each bus (including the
KEY
bus), the
SHIFT
button is used to access video and key sources that
have been mapped to crosspoints
beyond
the number of available buttons. The mapping itself is
performed during the installation procedure.
Excluding the
BLACK
crosspoint, please note:
•
On the Synergy 2, active crosspoints
19
through
33
can only be accessed via
SHIFT
.
•
On the Synergy 3, active crosspoints
32
through
59
can only be accessed via
SHIFT
.
•
On the Synergy 4, active crosspoints
37
through
69
can only be accessed via
SHIFT
.
Accessing a Shifted Source
Use the following procedure to access a shifted source on any bus:
1. Press and hold the
SHIFT
button.
Operating
Tip
You can double press the
SHIFT
button to have the MLE remain in the
shifted mode. When you need to access an
unshifted
crosspoint, you
can press
SHIFT
and the crosspoint. Double pressing the
SHIFT
button again releases the MLE from the shifted mode.
Содержание SYNERGY 4000DR-003
Страница 1: ...Ross Video Limited Operation Guide Volume I Software Issue 18...
Страница 10: ......
Страница 42: ...1 26 Introduction Synergy Series Operation Guide v18...
Страница 64: ...2 22 Control Panel Introduction Synergy Series Operation Guide v18...
Страница 132: ...4 54 Switcher Basics Synergy Series Operation Guide v18...
Страница 242: ...7 68 Keying Synergy Series Operation Guide v18...
Страница 280: ...8 38 Memory Functions and More Synergy Series Operation Guide v18...
Страница 310: ...GL 4 Glossary of Terms Synergy Series Operation Guide v18...
Страница 332: ...IX 22 Index Synergy Series Operation Guide v18...