4999DR-071-05
Calrec Omega Digital Audio Mixing
System
Requirements
• Large Audio Mixer Interface Software Option
• Serial Interface Cables DB9
• If the cable connection between the switcher and the Calrec
Omega is longer than 50 feet, an RS-232 to RS-422 converter is
required at the Calrec Omega.
Port Connections
Pinouts
Switcher Setup
To Set Up Communications
1.
Press
HOME
Setup
Installation
Com Setup
Type
.
• Use the
Com Port
knob to select the
Remote
X
port that you
connected the Calrec Omega to.
• Use the
Device
knob to select
Audio Mixer
.
2.
Press
Select Device
.
• Use the
Device
knob to select
RAP
.
3.
Press
Com Type
.
• Use the
Type
knob to select
RS-232
(
RS-232 NULL
on the
Synergy 1
).
4.
Press
Com Settings
.
• Use the
Baud
knob to select
115200
.
• Use the
Parity
knob to select
ODD
.
5.
Press
Extra Options
.
6.
Press
HOME
Confirm
.
To Assign Audio Channels to BNCs
1.
Press
HOME
Setup
Installation
BNC
Audio
.
2.
Use the
BNC
knob to select the Input BNC that you want to
assign an audio channel to.
3.
Use the
Audio 1
knob to select an audio channel, or group, that
you want to assign to the selected Input BNC.
4.
Use the
Audio 2
knob to select another audio channel, or group,
that you want to assign to the selected Input BNC.
5.
Press
HOME
Confirm
.
Refer to your switcher manual for information on creating audio
groups, or setting default audio levels.
Device Setup
Ensure the port on the Calrec Omega Digital Audio Mixer that is
connected to the switcher is configured for RS-232.
Compatibility
Switcher
Audio Mixer
Communications
REMOTE Port
(female)
RS-232
Switcher
Calrec Omega
2 (Tx)
3 (Rx)
3 (Rx)
2 (Tx)
5 Ground
5 Ground
Extra Options
Value
TargetMachine
Calrec
OD Master
M1 (default)
Audio Mixer
Version
Calrec Omega Digital Audio Mixer
--
Switchers
Synergy 1 SD
--
Synergy Series SD
18.0 or higher
Synergy MD/X
8.2 or higher
Vision MD/X
8.2 or higher
Vision QMD/X
8.2 or higher
Vision MultiPanel Support
--
Automation
OverDrive
6.0 or higher
Port Expanders
BSS4
Comtrol DeviceMaster
a
a.
You must set
Server/Client
to
Server
on the
Com
Settings
of the
Communications Menu 1-2
when
connecting to a Comtrol DeviceMaster.
Extra Options
Value