Solution
Description
Error
Ensure that you have
the correct control
panel connected to
the frame. If the
problem persists,
download the latest
upgrade file from and
force an upgrade of
the switcher. Contact
Ross Video Technical
Support for assistance
if you are unsure
about upgrading your
switcher.
The frame does not
recognise the control
panel. This could be
caused by an
unsupported panel
being connected to
the frame, or a
problem with the
panel module
controlled or the
configuration files.
Unknown
panel
type
Please
upgrade
Switcher Reset
If required, the switcher can be reset to return
it to a user-defined default setting (RState), or
the factory default state. A reset can be
performed for the entire switcher, or individual
components, such as keys.
Custom Reset Settings (RState)
You can customize many of the default switcher
parameters and save them as a user-defined
reset settings. These custom reset settings can
then be recalled when you want to return the
switcher to a previous state.
To Save a Custom Reset Setting
The Custom Reset Setting, or RState, saves how
you want the switcher to be configured when it
powers up, or when you recall the RState
manually.
1.
Click
Navigation Menu
>
Live Assist
>
Memory
>
RState
.
2.
Click
AuxX
,
MediaX
,
MiniMEX
, and
CanvasX
to select the buses or channels that are reset
with a switcher reset.
Note:
If Disable Audio Memories is set to On (Click
Navigation Menu > Configuration > System > Global)
the audio attributes are disabled.
Tip:
Click the All button to select or de-select all the items
in that category.
3.
Click
Save RState
and
Yes
.
To Load a Custom Reset Setting (RState)
The Custom Reset Setting, or RState, is recalled
every time the switcher is powered on, or it can
be recalled manually.
1.
Click
Navigation Menu
>
Live Assist
>
Memory
>
RState
.
2.
Click
Load RState
and
Yes
.
Tip:
Click Default RState to load the default RState
settings.
Factory Default Settings
You can restore all or part of the switcher to the
factory default state. A factory default returns
all installation and personality settings are reset.
To Factory Reset the Switcher
Return the switcher to the factory default
settings.
1.
Click
Navigation Menu
>
Configuration
>
System
>
Reset
.
2.
Click a reset or clear button to return that
feature to the factory default sate.
•
Clear Memories
— clear all memory
registers on the switcher.
•
Clear CCs
— clear all custom controls on
the switcher.
•
Default Bus Map
— return the bus map
to the default mapping.
•
Factory Reset
— return the installation
and personality registers to the default
settings.
Frame DIP Switches
There are a number of DIP switches inside the
frame that are used to diagnose the operation
of the switcher.
Table 8: Ultra Frame DIP Switches
Description
DIP
This DIP switch is used to set the IP address
of ethernet port on the frame to the default
value (192.168.0.123). It must be in the up
(off) position to set another IP address for
the frame.
1
130 • Diagnostics — Ultra User Manual (v6.6)
Содержание Carbonite Ultra Series