2.
Move the positioner backwards and forwards, left
to right, and twist the positioner left and right a
few times.
3.
Move each fader from one limit to the next a few
times. Do not push the fader hard when it reaches
the limit.
4.
Press
MENU
to save the calibration information.
System Real-Time Clock/Date
The switcher uses an internal clock to generate the
time for the clock overlay for the MultiViewer.
To Set the System Real-Time Clock
1.
Press
MENU
>
Config
>
NEXT
>
Clock
.
2.
Press
Time
.
3.
Use the
Hour
,
Minute
, and
Second
knobs to
select the current time.
4.
Press
Hour
.
5.
Press
Confrm
.
To Set the System Date
1.
Press
MENU
>
Config
>
NEXT
>
Clock
.
2.
Press
Date
.
3.
Use the
Month
,
Day
, and
Year
knobs to select
the current date.
4.
Press
Month
.
5.
Press
Confrm
.
Diagnostics
Diagnostics consist of a number of tests that are used
to confirm the functionality of switcher components.
Frame Diagnostic LEDs
There are a number of LEDs inside the frame that are
used to diagnose the operation of the switcher.
Figure 9: Frame Diagnostic LEDs
•
FRM UPGD
— is lit when the software on the
frame is being upgraded
•
1 (heartbeat)
— flashes to indicate normal
operation of the frame
•
2 - 8
— unused
•
PANEL
— is lit when the frame has proper
connection to a legacy Carbonite control panel
connected to the PANEL port at the back of the
frame
•
MC
— is not used at this time
•
POWER
— is lit when the frame is on
•
PS1
— is lit when power supply one is getting
power
•
PS2
— is lit when power supply two is getting
power
Frame DIP Switches
There are a number of DIP switches inside the frame
that are used to diagnose the operation of the switcher.
Table 7: Carbonite Black Frame DIP Switches
Carbonite/Carbonite Black Frame DIP Switches
DIP
Description
1
This DIP switch forces a RAM test every time the
switcher is powered on. It is in the up (off) position
by default.
2
This DIP switch is unused and should be left in the
default up (off) position.
3
This DIP switch is used to set the IP address of
ethernet port 1 on the frame to the default value
(192.168.0.123) and ethernet port 2 to DHCP. It
must be in the up (off) position to set another IP
address for the frame.
4
This DIP switch prevents software upgrades. It
must be in the up (off) position to upgrade the
switcher.
5
This DIP switch is unused and should be left in the
default up (off) position.
6
This DIP switch is unused and should be left in the
default up (off) position.
7
This DIP switch is unused and should be left in the
default up (off) position.
8
This DIP switch is unused and should be left in the
default up (off) position.
Control Panel DIP Switches
The up position for the DIP switch is OFF.
DIP1 DIP2 DIP3 DIP4 Function
OFF OFF
User IP Settings
OFF ON
Force DHCP IP
ON OFF
Force Static IP (192.168.0.129)
ON ON
reserved
OFF
reserved
ON
reserved
OFF Default Boot
ON Boot from memory card
Note:
When you force the static IP, the IP address of the
frame is also set (192.168.0.123).