6.
In the
Response Time
area, select how quickly the server executes the Clip Play command after the Clip Load
command.
•
Fast
— executes the play command immediately after the load command. This is recommended when
controlling the server from an external switcher.
•
Accurate
— executes the play command only after receiving confirmation that the clip has loaded. This is
recommended when controlling the server from an automation system.
7.
In the
Channel Control Port
area, select whether you want to use the serial ports or ethernet connection for the
channels assigned to the room.
Note:
The Tria+ UHD does not have an serial port for device control. You must select
Ethernet
.
8.
In the
Edit Timing
area, select a timing offset for when you are controlling the server from an external editor over
serial.
•
Timecode Alignment
— select the offset, in frames, of the timecode information that is sent to the editor
during playout or record.
•
Source Alignment
— select the offset, in frames, of the timecode information that is sent to the editor during
playout.
•
Out Point Offset
— select the offset, in fields, of the out-point timecode value that is sent to the editor during
record.
9.
In the
Video Edit Effect
area, select which tracks get recorded when an external editor issues the Video Record
command to the server.
•
Edit Video Track
— only the video track is recorded.
•
Edit Key Track
— only the alpha (key) track is recorded.
•
Edit Video and Key Tracks
— both the video and alpha (key) tracks are recorded. The clip loaded into the
VKA channel transport must have an alpha track.
10.
In the
VDCP Configuration
area at the bottom of the window, select specific configurations for the protocol you
are using.
• Select
Louth Preview
to allow clips to be pre-cued in the background for seamless back-to-back transitions
during playout.
• In the
Maximum length of Clip Name
field, select the maximum length of a clip name that is reported to the
controlling device.
11.
Click on the
Ch-
X
:
list and select the room that you want to assign to the channel.
12.
Click
Restart Tria
. A confirmation dialog box is displayed.
13.
Click
Restart Tria
to restart the server application and services with the new setting.
14.
Click
OK
when the restart has completed to dismiss the window.
To Configure a Room for the AMP Protocol
Set up a Room to use the AMP protocol to control server channels.
Note:
When controlling the server from a remote device over ethernet, you must select the port on the server corresponding to the
channel you want to send commands to. Channel transport A = port 8000, channel transport B = port 8001, and so on.
1.
Launch the
Tria Config
application.
You may be prompted to allow the program to make changes on the computer, click
Yes
.
Tria+ UHD User Manual — Remote Control Support •