Connected LED/3 Beepers/Short LED/Numbered LEDs: If the Connected LED lights, the Beeper emits 3 beeps, 

and the Short LED lights, the cable has a fault. The numbered LEDs indicate the location of a short.     

Note: 

In the Short mode, the Numbered LEDs only indicate the location of the shorts.    The other connections in the cable are 

not indicated.    If more than 3 numbered LEDs light, there may be multiple shorts in the cable.     

 

Connected LED/2 Beepers/Cross LED/Numbered LEDs: If the Connected LED lights, the Beeper emits 2 beeps, 

and the Cross LED lights, the cable has a fault.     

Note: 

In the Cross-mode, the Numbered LEDs indicate connections but do not indicate the location of the cross. RJ-11 cables 

used for telephone connections are often crossed.    Even new cables are often crossed.  This seldom affects the 

performance of standard analog telephone lines (POTS).    Digital telephone lines and old touch-tone phones may be 

polarity sensitive, so a crossed cable may prevent them from working properly. 

 

 

7.

 

CABLE REPAIR 

General Information   

The following section provides information to the user about common cable types, common failures, and repairs.  It is 

not meant to be an exhaustive study of the topic, just some basic information that the uninitiated may find helpful.     

 

Cable Damage   

When a cable tests badly, either the wire or the connectors or both may be at fault.    If the cable has been installed and 

working, then it’s likely that the wire or connectors have been abused in some way.    The wire portion of the cable can be 

damaged by being crushed (under the left of a desk), stretched (pulled sharply around a corner), punctured (by a nail or 

staple), over loaded (hit by lighting), etc.    Similar abuses will damage the connectors on the ends of the cable.    The 

connectors can also be damaged by excessive insertion and the removal or flexing of the cable close to connector body.     

While the 5 in 1 can identify a bad cable, it can not determine if the wire or the connectors are at fault.    The user must 

examine the different parts of the cable to determine the cause of failure and take the appropriate steps to correct the 

problem.  

   

Which end is bad?   

The 5 in 1 like many cable testers, can not find the location of the fault, or even determine which end or connector is bad.   

It simply knows that a fault exists.    The user must locate the fault and take the appropriate action.     

 

Cables with Molded on ends   

Many cables have molded on ends that can not be opened up for repair.    The entire cable must be replaced, or the 

molded on end removed and replaced with a user serviceable connector.    These types of cables usually fail from Opens 

or Shorts.    They seldom fail from a Crossed connection.     

 

Содержание RTK-T05

Страница 1: ...5 in 1 Cable Tester RTK T05 User Manual...

Страница 2: ...esult in damage to the tester or injury to the user Repairs and maintenance must only be carried out by qualified service personnel or qualified electricians technicians who know the dangers of and th...

Страница 3: ...ter Do not use the tester if there is evidence of chemical leakage from the battery 3 PRODUCT FEATURES Test 5 types of cables Simple one button tester Ergonomic portable handheld design Tests installe...

Страница 4: ...eased 6 status LEDs indicate the condition of the cable being tested as well as informing the user that Power is turned on and that the battery is good or bad 8 additional connection LEDs light to ind...

Страница 5: ...und that comes from the Main unit Interpreting the Results Power LED The Power LED should light whenever the Test Button is pressed and released It will stay in for a minimum of 5 seconds or for howev...

Страница 6: ...ormation that the uninitiated may find helpful Cable Damage When a cable tests badly either the wire or the connectors or both may be at fault If the cable has been installed and working then it s lik...

Страница 7: ...d cable But it may work just fine as crossover cable The 5 in 1 says my cable is good but it does not work on my LAN Many cable testers like the 5 in 1 only perform continuity style tests open short c...

Страница 8: ...used simpler approach is to replace the good cable with a reversed cable making the polarity come out correctly It is also worth knowing that some female female couplers reverse the polarity of the p...

Отзывы: