Rosewill R2-RAID Скачать руководство пользователя страница 1

 

 

 

   [ R2-RAID ] 

 

 

 

 

Server RAID System 

 

 User Manual 

 

—

 

Include 

Hardware Installation Guide 

Operation Guide 

HDD Formatting Guide 

Software Installation Guide

 

Operation Notice: 

In avoidance of HDD's temperature going too high, be sure to turn on the FAN. 

 

 

 

 

Thank you for purchasing a quality Rosewill Product. 

Please register your product at : www.rosewill.com/    for complete warranty information and future support for your product. 

Содержание R2-RAID

Страница 1: ...tting Guide Software Installation Guide Operation Notice In avoidance of HDD s temperature going too high be sure to turn on the FAN Thank you for purchasing a quality Rosewill Product Please register your product at www rosewill com for complete warranty information and future support for your product ...

Страница 2: ... Guide 3 Mode Selection Operation Guide 6 Raid Mode Selection 7 Gui Steelvine Manager Operation 7 Jumper Selection Storage Policy Definitions 9 Hard Drive Formatting Guide 16 Software Operation Guide 23 Software Installation Guide 23 Starting The Steelvine Manager 25 Introducing The Steelvine Manager 26 ...

Страница 3: ...D System R2 RAID User Manua 2 l About the 3 5 Dual SATA Disk Enclosure E F G C D A B Front View Rear View A Fan B eSATA Connector C Power Switch D USB Connector E Fan Switch F Power Adapter Socket G LED Indicator ...

Страница 4: ...Server RAID System R2 RAID User Manua 3 l Hardware Operation Guide Hard Drives Installation Guide STEP1 Release the 4 screws then pull out the rear panel and tray ...

Страница 5: ...Server RAID System R2 RAID User Manua 4 l STEP2 Place the two HDD into the tray Push the HDD to the end ntil the HDD is connected with SATA connector u STEP3 Screw the HDD on the tray both sides ...

Страница 6: ...Server RAID System R2 RAID User Manua 5 l STEP4 Push tray into Aluminum housing and secure them together Note Select operation mode first ...

Страница 7: ... mode only Always press reset button after changing the setting of switching jumpers Backup your data before formatting hard drives The device can support two equal or unequal capacity hard drives STEP1 Switch the power button to power on STEP2 Switch the power button to power on STEP3 Press reset button to reset the device Reset Button Switching Jumper ...

Страница 8: ...Mode Selection GUI SteelVine Manager Operation GUI SteelVine Manager is available only under GUI Mode STEP1 Install SteelVine Manager Please refer to page 23 STEP2 Start the SteelVine Manager Please refer to page 25 STEP3 Click on Configure Box icon ...

Страница 9: ...Server RAID System R2 RAID User Manua 8 l STEP4 Select Storage Policy then click Apply STEP5 Click Yes to continue ...

Страница 10: ...ed hard drive To select this mode the first time that the product is used ensure that the hard disk drives are installed set switching jumper on the back of the device to the GUI position and turn on the power In this mode no virtual volume s will be created until the storage policy and volume selections are made through the GUI To change from GUI mode to some other fixed storage policy thereafter...

Страница 11: ...OD should only be used if the SATA host controller provides Port Multiplier PM support If a host is not PM aware only a single drive is presented drive A No such limitation if using a USB host connection Drive A Drive B HD3206SRD Port 0 Port 1 Volume B Volume A Drive A Drive B HD3206SRD Port 0 Port 1 Volume B Volume A Equal hard drives Unequal hard drives ...

Страница 12: ... using only a single hard disk drive connected to Port 0 and then increase the storage capacity of the volume later by adding another hard disk drive to Port 1 and pressing reset button The new disk blocks of Port 1 will be concatenated to the end of the disk blocks of Port 0 and any data that is stored on the existing BIG volume will be preserved However it is not possible to expand an existing B...

Страница 13: ... no data redundancy Two unequal hard drives The capacity is double of the smaller hard drives Two equal hard drives The capacity is equal to the sum of both hard drives Drive A 250GB HD3206SRD Port 0 Port 1 Striping across disks Drive B 250GB Fast 500GB Drive A 250GB HD3206SRD Port 0 Port 1 Drive B 750GB Fast 500GB Striping across disks Unequal hard drives Equal hard drives ...

Страница 14: ...e When the offline drive comes back online the appliance begins a rebuild process immediately to restore data redundancy Although the volume remains available during the rebuild process the volume is susceptible to data loss through damage to the remaining drive until redundancy is restored at the end of the rebuild and verification process Host access takes precedence over the rebuild process If ...

Страница 15: ...TA host connection you must have a PM Port Multiplier aware host adapter when using SAFE33 on the top level node of a cascaded configuration so that ALL volumes can be detected by the host If your SATA host adaptor is not PM aware then ONLY the SAFE volume will be detected and the BIG volume will not be accessible No such limitation exists when using a USB host connection The size of the SAFE volu...

Страница 16: ... host connection you must have a PM Port Multiplier aware host adapter when using SAFE50 on the top level node of a cascaded configuration so that ALL volumes can be detected by the host If your SATA host adaptor is not PM aware then ONLY the SAFE volume will be detected and the BIG volume will not be accessible No such limitation exists when using a USB host connection The size of the SAFE volume...

Страница 17: ...ser Manua 16 l Hard Drive Formatting Guide STEP1 Right click on My Computer icon and select the Manage column STEP2 Select Disk Management and you will see your hard drives show Unallocated Sample 750GB 250GB hard drives JBOD MODE ...

Страница 18: ...Server RAID System R2 RAID User Manua 17 l BIG MODE RAID 0 FAST MODE ...

Страница 19: ...Server RAID System R2 RAID User Manua 18 l RAID 1 SAFE MODE RAID SAFE 33 MODE ...

Страница 20: ...Server RAID System R2 RAID User Manua 19 l RAID SAFE 50 MODE STEP3 Right click the red squared block and selects Initialize Disk Take JBOD MODE for example one 750GB HDD one 250GB hard drives ...

Страница 21: ...Server RAID System R2 RAID User Manua 20 l STEP4 Press OK button to initialize hard drive STEP5 The hard drive will show Online Right click the Unallocated block and selects New Partition ...

Страница 22: ...Server RAID System R2 RAID User Manua 21 l STEP6 The New Partition Wizard will appear Please follow the instruction of the wizard to complete the partition ...

Страница 23: ...Server RAID System R2 RAID User Manua 22 l STEP7 When new partition is completed the hard drive will be recognized as a New Volume STEP8 Format the other hard drive in the same way ...

Страница 24: ...em R2 RAID User Manua 23 l Software Operation Guide Software Installation Guide STEP1 Insert driver CD to the CD ROM drive STEP2 Select Install GUI icon to install the driver STEP3 Please follow the wizard to complete ...

Страница 25: ...Server RAID System R2 RAID User Manua 24 l ...

Страница 26: ... i c o a g e F i l e s S i c o a g e F i l e s S i c o a g e i l e s S i c o a g e l e s S i c o a g e e s S i c o a g e s S i c o a g e S i c o a g e S i c o a g e S i c o a g e i c o a g e l c o a g e i c o a g e c o a g e o a g e n a g e a g e I a g e m a g e a g e g e e 5 S e e e 7 S e e e X S e e e X S e e e S e e e S e e e t e e e e e e e e l e V e i e n e e SteelVineManager Once started the...

Страница 27: ...G RAID 0 RAID 1 SAFE33 or SAFE50 mode In Status only mode you are not permitted to change the configuration from the GUI The only possible way to change the configuration is to change the switching jumper Configure Box Schedule Disk Verify Configure Popups View Policies Configure Email Notification Event Log Specify Firmware Backup Button Box Serial Number Drive Information System Status Drive Sta...

Страница 28: ...he field displays N A because there s no fan speed sensor installed in your storage enclosure Exp S N Shows the expected serial number The device compares the expected and actual drive serial numbers to detect when a drive s status changes Capacity Status Section Policy Shows the storage policy configured for each volume Total Shows the combined capacity of the volume Drive Shows capacity informat...

Страница 29: ...e or more SAFE volumes exist Configure Pop Ups Configure the Pop Up messages View Policy Settings Shows the Rebuild Policy settings that are defined by the GPI pins appears only when one or more SAFE volumes exist Email Notification Configure the operation of email message notification Show Event Log View the Event Log Specify Firmware View the current version or download an updated version of the...

Отзывы: