2-15
• Pt100 2-wire RTD:
Lead wire resistance seen by the transmitter = 150 m × 2 wires ×
0.025
Ω
/m = 7.5
Ω
Thermocouple or Millivolt Inputs
For integral mounting applications, the thermocouple can be
connected directly to the transmitter. If mounting the transmitter
remotely from the sensor, use appropriate thermocouple extension
wire. Make connections for millivolt inputs with copper wire. Use
shielding for long runs of wire.
Figure 2-12. Sensor Wiring Diagrams
Basic Error
Lead Wire Resistance
α
Pt
R
o
×
(
)
----------------------------------------------------------
=
Error due to amb. temp. variation
α
Cu
(
)
∆
T
amb
(
)
×
Lead Wire Resistance
(
)
×
α
Pt
(
)
R
o
(
)
×
-----------------------------------------------------------------------------------------------------------------
=
Basic error
7.5
Ω
0.00385
Ω
/
Ω °
C
(
)
100
Ω
(
)
×
---------------------------------------------------------------------------------
19.5
°
C
=
=
Error due to amb. temp. var. of
25 °C
±
0.0039
Ω
/
Ω °
C
(
)
25
°
C
(
)
×
7.5
Ω
(
)
×
0.00385
Ω
/
Ω °
C
(
)
100
Ω
(
)
×
-------------------------------------------------------------------------------------------------------
1.9
°
C
±
=
=
Model 244E Sensor Connections
* Rosemount Inc. provides 4-wire sensors for all single element RTDs. You can use these
RTDs in 3-wire configurations by leaving the unneeded leads disconnected and insulated
with electrical tape.
** The transmitters must be configured for a 3-wire RTD in order to recognize an RTD with a
compensation loop.
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
644-
0000
B
0
1A
1
2-wire
RTD
and
V
3-wire
RTD
and
V
4-wire
RTD
and
V
T/C
and mV
RTD with
Comp.
Loop
*
**
Содержание FISHER-ROSEMOUNT 244EH
Страница 1: ...Models 244EH and 244ER PC Programmable Temperature Transmitters 00809 0100 4737 English Rev EA ...
Страница 8: ......
Страница 34: ......
Страница 46: ......
Страница 51: ...B 5 Figure B 1 Canadian Standards Association CSA Intrinsic Safety Installation Drawing 00644 1064 Rev AB ...
Страница 53: ...B 7 Figure B 3 Factory Mutual FM Intrinsic Safety Installation Drawing 00644 0009 Rev AA 644 0009A01A ...