Reference Manual
00809-0100-4022, Rev AA
July 2002
Model 4600
www.rosemount.com
Section 3
Configuration
Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1
Commissioning on the Bench with HART . . . . . . . . . . . . page 3-2
Model 275 HART Communicator . . . . . . . . . . . . . . . . . . . . page 3-4
Review Configuration Data . . . . . . . . . . . . . . . . . . . . . . . . page 3-5
Check Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-6
Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-7
Detailed Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-10
Diagnostics and Service . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16
Advanced Functions for HART Protocol . . . . . . . . . . . . . page 3-18
Multidrop Communication . . . . . . . . . . . . . . . . . . . . . . . . . page 3-21
OVERVIEW
This section contains information on commissioning and tasks that should be
performed on the bench prior to installation. This section contains the Model
4600 HART configuration information.
HART Communicator and AMS instructions are given to perform configuration
functions. For convenience, HART Communicator fast key sequences are
labeled “Fast Keys” for each software function below the appropriate
headings.
SAFETY MESSAGES
Procedures and instructions in this section may require special precautions to
ensure the safety of the personnel performing the operations. Information that
raises potential safety issues is indicated by a warning symbol ( ). Refer to
the following safety messages before performing an operation preceded by
this symbol.
Warnings
Explosions can result in death or serious injury.
• Transmitters located in hazardous areas should be installed in accordance with
local codes and requirements for that area.
• Verify that the operating atmosphere of the transmitter is consistent with the
appropriate hazardous locations certifications.
Electrical shock can result in death or serious injury.
• Avoid contact with the exposed leads and terminals. High voltage that may be
present on leads can cause electrical shock.
Содержание 4600
Страница 2: ......
Страница 4: ......
Страница 8: ...Reference Manual 00809 0100 4022 Rev AA July 2002 Model 4600 TOC 4 ...
Страница 20: ...Reference Manual 00809 0100 4022 Rev AA July 2002 Model 4600 2 10 ...
Страница 54: ...Reference Manual 00809 0100 4022 Rev AA July 2002 Model 4600 4 12 ...
Страница 64: ...Reference Manual 00809 0100 4022 Rev AA July 2002 Model 4600 B 2 ...
Страница 67: ......