6
Rosco Maximizer 3B Asphalt Distributor
6-21
Operation
Fumes from asphalt materials can be
poisonous. When using the top opening, the operator
should stand up-wind and to one side to avoid hot
gases, fumes or being struck by a cover or hot
asphalt spray.
4. Move the Maximizer 3B to the storage tank or
transfer vehicle.
Never operate burner equipment when
the vehicle is being loaded or in transit. The flue
tubes can become exposed, causing an explosion
inside the tank, or material being sprayed could
ignite.
Always wear protective clothing,
gloves and a face shield. Contact with hot asphalt
can cause severe burns.
5.
Turn the Plus One Controller Master switch ON to
activate the system, (
).
6. Set the Plus One Controller Auto/Manual selection
to MANUAL.
7. Set the Plus One Controller Mode Selection control
to LOAD.
8. Set the Plus One Controller Pump Control priority
selection to REAR.
9. Set the Plus One Controller Spraybar Master
selection to OFF or BAR CRCLT.
10. Using Rear Controller (
Pump Speed dial slowly in FORWARD direction to
provide suction to the line (50 - 75 GPM).
Load Line and Transfer Line
Figure 6-15
Modes Of Operation
The remainder of this section will explain the different
modes of operation for the Maximizer 3B Asphalt
Distributor. Each function is explained in detail and
includes safety concerns that the operator must be
aware of when operating the unit.
With each mode, there are illustrations to show the
correct mode control selections and the path of travel of
asphalt flow in the system. The flow illustration shows the
proper orientation of the valves throughout the system.
The illustrations may also be used to help troubleshoot
the unit if a certain mode does not operate properly.
When operating the unit for the first time, be sure to read
each mode section carefully before operating in that
mode. Keep this book handy for reference during each
mode of operation. If you are unsure how to perform a
function with the unit, reread the instruction or seek the
help of trained, experienced personnel.
Load Mode
Bottom Tank Loading
1. Review and follow the Pre-Operating Check List
earlier in this section before starting.
2. Be sure the unit is sitting on a level area.
Do not put your head in the tank.
Serious injury or death could result from breathing
poisonous fumes.
3.
With a flashlight, look into the tank from the top and
check for water or condensation in the bottom of
the tank. If necessary, drain the tank contents into
an approved container before loading. Dispose of
material and water according to local, state and
federal regulation.
DO NOT SMOKE around the machine.
Fuel, asphalt material and the fumes from both
can explode when exposed to flame or heat from
smoking or other sources.
Hot material will turn water into steam
and can cause an explosion.
Check that the material being loaded
is compatible with the previously used asphalt,
(see
Some asphalt material can be vaporized by high
temperature materials and can explode. If material is
not compatible, clean out the tank.
Return to
Last Viewed
Содержание Maximizer 3B
Страница 1: ...Operations Service And Parts Manual Rosco Maximizer 3B Asphalt Distributor Manual No 1005234 01 ...
Страница 2: ......
Страница 12: ...NOTES Rosco Maximizer 3B Asphalt Distributor 1 2 Introduction Return to Last Viewed Return to Thumb Index ...
Страница 20: ...NOTES 2 8 Safety Rosco Maximizer 3B Asphalt Distributor Return to Last Viewed Return to Thumb Index ...
Страница 108: ...NOTES Rosco Maximizer 3B Asphalt Distributor 6 52 Operation Return to Last Viewed Return to Thumb Index ...
Страница 138: ...NOTES Rosco Maximizer 3B Asphalt Distributor 8 12 Troubleshooting Return to Last Viewed Return to Thumb Index ...
Страница 140: ...NOTES Rosco Maximizer 3B Asphalt Distributor 9 2 Schematics Return to Last Viewed Return to Thumb Index ...
Страница 142: ...9 4 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 144: ...9 6 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 146: ...9 8 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 148: ...9 10 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 150: ...9 12 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 152: ...9 14 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 154: ...9 16 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 156: ...9 18 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 158: ...9 20 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 160: ...9 22 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 162: ...9 24 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 164: ...9 26 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 166: ...9 28 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 168: ...9 30 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 170: ...9 32 Schematics Rosco Maximizer 3B Asphalt Distributor Notes Return to Last Viewed Return to Thumb Index ...
Страница 363: ......