7  ROUTINE MAINTENANCE 

The ROS Lightning is intended to be maintenance free. Be sure to clean your lamp with 
fresh water after each deployment. A visual inspection is always helpful in assessing the 
integrity of the lamp. In the event the lamp stops working, please contact ROS customer 
service. For troubleshooting see Section 8.  
 
 

8  TROUBLESHOOTING 

Problem  

Typical Causes 

Action 

Product won’t power on 

Not connected properly 

Check cables and power 
supply 

 

 

Check wiring 

 

 

Verify your have serial 
communication 

 

 

Verify proper input power 

Communication issues 

Not connected properly 

Verify RS-485 to RS-232 
converter is plugged in 
correctly 

 

 

Verify correct COM port 

Light is dimly lit 

Over temperature 

Allow light to cool 

Condensation or water on the 
window 

Connector leak or o-ring seal 
failure 

Return to ROS for repair 

 

9  REFERENCE DOCUMENTS 

DOC NUMBER 

ROS DOCUMENT DESCRIPTION 

10-00234 

APPLICATION NOTE, INTERCONNECTING RS-485 COMPONENTS 

21-30022 

RS-485 COMMUNICATION PROTOCOL 

21-30034-01 

HELIOS CONTROL SOFTWARE 

10-20099 

INSTALLATION AND OUTLINE DRAWING 

21-03030 

HELIOS MANUAL 

 
 

Содержание ROS Lightning

Страница 1: ...10 00640 REV A OPERATION AND MAINTENANCE MANUAL 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 858 565 8808 www rosys com ROS Lightning...

Страница 2: ...ORD 1 1 WARNINGS 2 2 DESCRIPTION 2 3 PART NUMBER CONFIGURATION 3 4 PRODUCT SPECIFICATIONS 2 4 1 GENERAL SPECIFICATIONS 2 4 2 LIGHT OUTPUT 3 5 INSTALLATION GENERAL FUNCTIONALITY 3 6 CONNECTOR WIRING CO...

Страница 3: ...of the State of California shall govern this warranty In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS discretion the prod...

Страница 4: ...stance during installation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction please contact our agent in you...

Страница 5: ...10 00640 REV A 1 CHANGE RECORD REV DESCRIPTION DATE X1 SEE EC 01258 12DEC12 A SEE EC 01564 15APR13...

Страница 6: ...t to comfortably touch the Lightning with your bare hand 2 DESCRIPTION The ROS Lightning LED lamp is a revolutionary underwater LED lamp Its technology gives the end user the capability of having a la...

Страница 7: ...R PHASE CONTROL IS NOT AVAILABLE WITH 24 VDC AL X X X X X X X X X N A X X 01 MCBH 4 MP SS SUBCONN 02 LPMBH 4 MP BRASS IMPULSE 03 BH 4 MP BRASS SUBCONN 04 SEANET 101 SS SCHILLING 07 5507 1503 SS SEACON...

Страница 8: ...depending on external connector End of Life Light Output 70 Rated Intensity 50 000 Hrs Optical Color Temperature 6200 K Nominal Lumen Output Floodlight 10 000 Lumen Nominal Spotlight 8 000 Lumen Nomin...

Страница 9: ...act your sales representative for any issues with your new LED lamp To install your new LED lamp use the bolt pattern provided on the back of the lamp or an available ROS mounting clamp Note that your...

Страница 10: ...on 1 Ground 1 Ground 1 Ground 2 24 VDC 2 24 VDC 2 26VDC RET 2 24 VDC 2 Load 2 Load 2 Load 3 RS 485 A 3 Analog Dimming Input 3 GND 3 Neutral 3 Neutral 3 Neutral 4 RS 485 B 4 N C 4 RS 485 A 4 DC Common...

Страница 11: ...ower on Not connected properly Check cables and power supply Check wiring Verify your have serial communication Verify proper input power Communication issues Not connected properly Verify RS 485 to R...

Отзывы: