Chapter 5: Subsystem Maintenance and Upgrading
Replacing
a Faulty PSU
5-15
WARNING!
When a PSU is removed from the chassis, the cooling module is
also removed from the chassis.
It is recommended that the replacement procedure is completed in
less than five (5) minutes to prevent the subsystem from
overheating.
Step 7.
Insert the replacement module.
Make sure the extraction
handle is held at its up-most position so that the saddle
notches on the sides of the handle can snap onto the metal
protrusions along the interior walls of the PSU slot. Push the
PSU into chassis, and when you feel the contact resistance,
push the handle downward to secure the module. (See
Section 5.6.
)
Figure 5-14: Installing the PSU
Step 8.
Secure the PSU to the subsystem
by fastening the retention
screw through the PSU extraction handle. (See
Figure 5-15
)