Page | 9
TF 200.01.0040_ENG
5.3
Testing
After mounting the battery on the 4Single Frame, and before putting it into use, the frame must be tested to
ensure that it functions properly, and that the safety is upheld.
Afterwards, it is recommended to test the function of the 4Single Frame at least once a year, by qualified
personnel.
5.3.1 Before testing the frame
a) Ensure the battery has been mounted according to the mounting instructions
b) Check that all bolt connections are fastened tightly
c) Check that all the cables are mounted correctly, and the plugs are pushed in fully
d) Remove any objects from on top of the tabletop, so that there is no load on the frame
e) Make sure that the table can drive unhindered upwards and downwards, without the table hitting any
objects
5.3.2 Testing the frame
a) Press the DOWN button on the control, until the table is in its bottom position. Let go of the button
and press DOWN again for 5 seconds. The legs should move below the bottom position. This resets
the control box. Check if the movement is even and controlled.
b) Press the UP button on the control, until the table is in its top position. Check if the movement is
even and controlled.
5.3.3 Testing the safety-strip
a) If a safety-strip has been mounted under the fascias, press the DOWN button on the control, let the
table drive 2-5cm / 0.8-2in, then press the safety-strip. The table should retract 1-2cm / 0.4-0.8in,
then stop completely.
If all the items have been checked, and the table functions properly, it can be put into use.