6.3 Performance test
After mounting and prior to use all functions of the table must be tested. After that a
performance test must be carried out at least once a year by competent personnel:
Testing prior to switching on power:
1.
Check that the mounting instructions have been observed.
2.
Check that all bolts have been tightened.
3.
Check that all cables have been connected correctly and that the plugs have been
pressed home.
4.
There must be no load on the table.
5.
There must be no objects or the like preventing the table from moving freely within the
range of height adjustment.
Start-up Procedure
1. Connect the net cable and turn on the power
2. Connect the motor cables to M1 and M2
3. Connect the control switch to HS
4. Press DOWN on the control switch, move the frame to bottom position, check that the
movement is even and smooth. Make sure that the hose connections follow the
movement of the frame and that they do not get squeezed. The frame is now reset.
5. Press UP on the control switch, move the frame to top position and check that the
movement is even and smooth. Make sure that the hose connections follow the
movement of the frame and that they do not get squeezed.
If a safety strip has been mounted under the tabletop it must be tested:
Press the DOWN button and let the table move 2-5cm downward while activating the
safety strip. The table must now stop the downward movement, move1-2cm upward and
stop.
When all these tests have been carried out the table is ready for use.