Device functions
Version 1
RES-5009
Page 29
9
Device functions
See also section 7.6 "Wiring diagram (standard)" on page 19.
9.1
Display elements and operating elements
The LEDs display additional operating statuses of the controller besides the functions in the above illustration.
These operating states are shown in detail in the following table:
LED
blinks slowly (1 Hz)
blinks quickly (4 Hz)
on permanently
AC (AUTOCAL)
(yellow)
RS bit set (reset) or wait for
line voltage
AUTOCAL requested, but
function is blocked
AUTOCAL is carried out
LED blinks with a different frequency:
Incorrect (too low) supply voltage
OUTPUT
(green)
In control operation, the light intensity is proportional to the heating current.
HEAT
(yellow)
—
START requested,
but function is blocked
START is carried out
ALARM
(red)
Configuration error,
AUTOCAL not possible
Controller incorrectly cali-
brated, carry out
AUTOCAL
Error,
chap. 9.15
ERR
(green
)
LED
(red
)
LED
BUS POWER
RUN
24 V POWER
(green
)
LED
(green
)
LED
Lights up or blinks according
to the CAN protocol used.
Lights up or blinks according
to the CAN protocol used.
Lit if internal power supply for
CAN interface is OK.
Lit if external 24 VDC power
supply is present.
12 13 14 15 16 17 18
9
8
6
5
10 11
7
4
3
2
1
Vi s u a l
AC
HEAT
OUTPUT
ALARM
ERR
RUN
BUS POWER
24 V POWER
www.
.de
ROPEX
Made in Germany
RES-5009
CAN
!
PROCESS CONTROL
EQUIPMENT
E464680
RESISTRON
(green
)
LED
AC
(yellow
)
LED
OUTPUT
(yellow LED)
ALARM
HEAT
(red
)
LED
Indicates pulses in
measurement mode. In control
mode, luminous intensity is
proportional to heating current.
Remains lit for duration of
AUTOCAL process.
Lit during heating phase.
Lights up or blinks to indicate
ALARM.
Содержание RESISTRON RES-5009