Montage und Installation
Version 1
RES-409
Page 15
4. Wire the system in accordance with the instructions in section 8.3 "Power supply" on page 17, section 8.6
"Wiring diagram (standard)" on page 20 and the ROPEX Application Report. The information provided in
section 8.2 "Installation steps" on page 16 must be additionally heeded.
5. Connect the RESISTRON
®
temperature controller to the CAN master using a cable according to IEC 947-5-2.
Check the tightness of all system connections, including the terminals for the impulse transformer
winding wires.
6. Make sure that the wiring conforms to all relevant national and international installation regulations.
!