Controller functions
Version 1
RES-402
Page 19
7
Controller functions
See also section 5.6 "Auxiliary voltage" on page 13.
7.1
Indicators and controls
Manufactured as of January 2006
Manufactured up to December 2005
Yellow LED, remains lit for duration
of AUTOCAL process.
Green LED, indicates pulses in measure-
ment mode. In control mode, luminous
intensity is proportional to heating current.
Yellow LED, lit during heating phase.
Red LED, lights up or blinks to indicate ALARM.
4
3
2
1
18
17
16
15
14
13
12
11
10
9
8
7
6
5
Button for manual activation of AUTOCAL
function (zero calibration). Do not press
unless heatsealing band is cold.
RESISTRON
RES- 402
Made in Germany
ROPEX
Tel:+49(0)7142-7776-0
Temperature
controller
AUTOCAL
OUTPUT
HEAT
ALARM
Yellow LED, remains lit for duration
of AUTOCAL process.
Green LED, indicates pulses in measure-
ment mode. In control mode, luminous
intensity is proportional to heating current.
Yellow LED, lit during heating phase.
Red LED, lights up or blinks to indicate ALARM.
4
3
2
1
ROPEX
INDUSTRIE - ELEKTRONIK
.
RESISTRON
μ
P-Controller
!
18
17
16
15
14
13
12
11
10
9
8
7
6
5
AUTOCAL
OUTPUT
HEAT
ALARM
Button for manual activation of AUTOCAL
function (zero calibration). Do not press
unless heatsealing band is cold.