background image

TR9016

Dual Flush Sensor Flush Plate

Please read completely before commencing.  Retain for future reference

Installation & Operation Instructions - For Domestic Use Only

Introduction

Battery Installation 

(Batteries not included)

Installation

This sensor flush plate is compatible with wall hung frame cisterns and In-wall cisterns from Roper Rhodes 

Group.

For In-wall installation the front of frame to front of finished wall minimum depth should be 15.5mm.

If used with a furniture concealed cistern ensure a clearance of 105mm is left between the cistern and the front 

of the furniture fascia surface to allow adequate installation.

1. Cut the protective casing of the in-wall cistern in-line with the 

finished wall surface.

3. Remove the front fascia panel completely.  Push the glass front to the 

top and tilt the top towards you.  Un-clip the glass fascia by expanding 

the clip links and keep aside until installation is completed.  Remove 

the battery holder also to 

avoid damage

.

Open the glass plate by pushing it towards the top and then tilting it 

forwards.  The clip chain will allow it to hang, make sure it’s secured 

before dropping it. 

2. Screw the fixing arms (supplied in the box) onto the cistern.

The rods may need cutting down depending on the thickness of the 

finished wall/surface.

Good quality Alkaline batteries will last for approximately one year in 

normal domestic conditions.

Once batteries are due to be replaced, a continuous alarm will be heard 

for 10s, indicating that battery power is low and that they are due to be 

changed.  The LED lights will also flash.

Batteries are totally exhausted when the LED lights are continuously 

flashing (twice per second).  Please replace the batteries immediately.

A manual over-ride button is available if batteries are totally exhausted.

Remove the battery holder and insert 4x AA batteries into the battery 

compartment, noting the polarity on the battery holder.  Slide back into 

place and replace the glass fascia.  The LEDs will Illuminate, indicating 

that the flush plate is ready to be used.

minimum

15.5mm

Fixing Arms

Battery 

    Holder

Clip links

1

2

1

2

Отзывы: