THERMOSTATIC SHOWER BAR VALVE

THERMOSTATIC SHOWER BAR VALVE

Installation & aftercare instructions

Please retain for future reference

SERVICE INTERVALS

Subsequent frequency can be determined with reference to previous test results. Where no significant deviation was 

recorded the test interval can be made equal to the maximum recorded interval to that point.

Note. Check valve and strainer servicing must be conducted at each test interval.

If the recorded mixed water temperature is greater than > 2°K from the initial recorded settings or the set point cannot 

be reached / stabilised further action is required.

It is important to establish that the incoming water supplies still satisfy the initial guidance and also that no additional 

draw off variation that could affect performance has occurred. 

The material selection for this valve has excellent resistance to scale build up and is designed such that there are no 

serviceable parts beyond items 1 & 2 as described previously.

In the very unlikely event that initial performance cannot be achieved, and all external parameters are correct, the unit 

may require replacement.

10-YEAR GUARANTEE

We have complete confidence in this Roper Rhodes product and as such it is offered with a 10-year guarantee against

defects in manufacture. The guarantee requires that this product be used in the manner for which it was intended and

that it is installed & maintained in accordance with the fitting instructions and local water bylaws. The guarantee

covers products in domestic use only.

The guarantee is invalidated should the valve be damaged by water borne debris. Make sure that supply pipes are clear

of any debris prior to installation, this is particularly important on new plumbing installations.

In the unlikely event that this product should fail during the guarantee period we will either replace the faulty part or the

complete unit as appropriate.

Содержание SV2207

Страница 1: ...ched stabilised further action is required It is important to establish that the incoming water supplies still satisfy the initial guidance and also that no additional draw off variation that could affect performance has occurred The material selection for this valve has excellent resistance to scale build up and is designed such that there are no serviceable parts beyond items 1 2 as described pr...

Страница 2: ... a position that maintenance of the TMV and its valves and the commissioning and testing of the TMV can be undertaken The fitting of strainers is recommended as close as is practicable to the water supply inlets of the thermostatic mixing valve HIGH PRESSURE LOW PRESSURE Maximum Static Pressure BAR Flow Pressure Hot Cold BAR Hot Supply Temperature C Cold Supply Temperature C 10 0 5 to 5 55 to 65 E...

Страница 3: ... deviate by more than 2 C of the initial set recorded result Record these findings 5 Record the measuring equipment used for the measurements The above records must be retained and updated during the service life of the TMV If there is a residual flow during the commissioning or the annual verification cold water supply isolation test then this is acceptable providing the temperature of the water ...

Страница 4: ...irmly locks the pipe in position Threaded connector Compression fitting Check valve Flow valve STORM BOTTOM OUTLET BAR VALVE SHOWN STORM BOTTOM OUTLET BAR VALVE SHOWN Increase flow Decrease temperature Increase temperature Decrease flow OPERATING STORM BOTTOM OUTLET BAR VALVE SHOWN Temperature Cartridge Connection nut Filter ...

Отзывы: