Intense, Oracle,
Reveal Illuminated Mirror
Installation & aftercare instructions
Please retain for future reference
INTENSEIN
TE
N
SE
MLE500
ORACLEOR
AC
LE
MLE510
REVEALRE
VE
AL
MLE520
REF: AR.RR.MLE500.510.520| 1.16 V2
Customer Services, Roper Rhodes Ltd, Brassmill Lane Trading Estate, Bath, BA1 3JF
Tel: 01225 303 900
|
Fax: 01225 448 877
|
Email: [email protected]
|
Web: www.roperrhodes.co.uk
ELECTRICAL SAFETY INSTRUCTIONS
ELECTRICAL SAFETY INSTRUCTIONS
(Applicable to UK Installations only)
All fittings must be installed by a competent person, in accordance with current IEE wiring
regulations. If in doubt consult a qualified electrician
IMPORTANT
Always switch off the electrical supply at the mains during installation and maintenance. It
is recommended that the fuse is withdrawn or the circuit breaker is switched off for the
necessary circuit before installation commences.
Fitting in Bathrooms is subject to the appropriate zone in accordance with IEE Regulations.
This product is suitable for zone 2 and outside zones. IT IS NOT suitable for installation in
Zone 0 or Zone 1. It is also not suitable for installation in saunas, steam rooms or shower
cubicles. This product is only suitable for permanent installation. DO NOT connect to a
trailing plug and socket outlet. Although this product has an Ingress Protection rating of
IP44 it is only suitable for indoor use. Do not attach the product to surfaces that are damp or
otherwise electrically conductive.
INSTALLATION CARE & SAFETY
INSTALLATION CARE & SAFETY
Wear suitable eye protection when drilling. Take care when using power tools near water -
the use of a residual current device (RCD) is advised. Beware of hidden cables or pipes.
Take care if drilling on tiled surfaces in case the drill slips. A piece of masking tape applied
to the wall before marking out the fixing holes will stop the drill from wandering.
DO NOT strike glass components with hard or pointed items. DO NOT place very hot or very
cold items against or in close proximity to glass surfaces unless an adequately thick
insulation material is used to prevent such items coming in contact with the glass.
The nominal thickness of the mirror glass used in this product is 5mm and is film backed for
safety. If the glass becomes chipped or broken replace immediately.
This product should be positioned well away from curtains and other fabrics. Never cover
the mirror. This product is heated, we recommend that it is turned off after use and should
never be left on for prolonged periods of time
This product could be dangerous and is only to be installed by a competent person.
CLEANING
CLEANING
It is recommended that the unit is cleaned with a soft, dry, non abrasive cloth when turned
off. Never use cleaning agents or abrasive materials on any type of surface finish. Do not
allow moisture to come into contact with the electrical components.
COMPLIANCE
COMPLIANCE
This product complies with all relevant British and European safety standards:
WIRING
WIRING
This product is manufactured to class I category and must have an earth connection.
COLOUR CODING:
L - Live
= Brown
N - Neutral = Blue
- Earth = Green & Yellow
LIGHTS
LIGHTS
.
To obtain a replacement LED lamp if faulty or broken contact customer services (see details
at foot of page) quoting product code.
2
2
2
OUTSIDE
OUTSIDE
ZONES
ZONES
2
ZONE
ZONE
1
0.75m
2.25m
3.0m
0.6m
0.6m
0.75m
Bathroom Zones Diagram
Bathroom Zones Diagram
Distances from a bath tub or shower tray