Page 12
Accura 7500 Communication
The default settings for serial communication of Accura 7500 are 8 data bits, even parity, and 1
stop bit.
RS485 Multi-drop Diagram
Warning
When connecting the communication cable to the terminal port[Ta, Tb], multi-drop connection
should be made. As shown in the above figure, T-branch connections can decrease communication
reliability.
To connect an RS-485 communication line to a PC[supports only the RS-232 port], a RS-485 to RS-
232 converter[RTS/CTS automatic control required] should be used. For communication between a
PC and Accura 7500, the RS-485 Data+(TRX) and Data-(TRX) lines of the converter should be
connected to the Ta and Tb ports on Accura 7500, respectively. The RS-232 port of the converter is
connected to the user PC.
Time Delay for RS-485 Communication
There are time delays between request packets and response packets.