Accura 2350-VDC User Guide
Chapter 2 Accura 2350-VDC Operation/Setup
ⓒ
2014 Rootech Inc. All Rights Reserved
Page 15
Button Operation
The SET button on the Accura 2350-VDC module is used to perform the following functions.
Display mode
Displays the module ID and DC input voltage
Setup
mode
Sets up the module ID and the DC input voltage parameter for each channel
Button
Function
[Display Mode]
Displays the module ID and DC input voltage
[Setup Mode]
Short press
1
Move to the setup mode.
(The setup menu is sequentially selected each time the SET
button is pressed.)
Long press
2
Preset values blink and can be changed.
Short press
Select a preset value to change by pressing the button.
(The setup value changes sequentially each time the button is
pressed.)
Long press
Save the selected setup value. And then the screen stops blinking.
(Move to the next setup menu.)
1. Press the button and release it immediately.
2. Release the button after pressing it for 1 second.
Note
If there is no button operation for 10 seconds in the setup mode, the screen automatically returns to
the display mode.