ClicSeam™ Safety and Installation Manual
12
Roof Slope
For the purposes of waterproofing as well
as maintenance, it is strongly recommended
the roof is at slope of more than 10 degrees.
Location of battens
Battens serve as a support for the Product, and therefore, must be installed on the
same level and form an even surface to eliminate the possibility of damage to the
glass layer during the installation.
Roofit
.solar recommends 250-300 mm gap between the horizontal battens. Ventilation
gap between the Product and the moisture barrier should be at least 50 mm.
Ensure the installation method and
supporting system of the roofing
materials are strong and durable
enough to install the Product and
meet its load conditions. The
supporting system must be
installed according to local,
national, or international standards.
Special attention must be paid to the
positioning of the battens in respect to
the installation of the Product. Each
Product has junction boxes that must be
placed in between the battens to
guarantee safe installation.
Junction boxes