Страница 1: ...R S RTB2000 Oscilloscope Getting Started 1333160502 Version 08 Q 52 ...
Страница 2: ...9 0 Email info rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners 1333 1605 02 Version 08 R S RTB2000 Throughout this manual products from Rohde Schwarz are indicated without the symbol e g R S RTB2000 is indicated as R S RTB2000 ...
Страница 3: ...n overview 16 2 1 Manuals and instrument help 16 2 2 Data sheet and brochure 17 2 3 Calibration certificate 17 2 4 Release notes and open source acknowledgment 17 3 Preparing for use 18 3 1 Lifting and carrying 18 3 2 Unpacking and checking 18 3 3 Choosing the operating site 19 3 4 Setting up the product 19 3 4 1 Placing the product on a bench top 19 3 4 2 Mounting the product in a rack 20 3 5 Con...
Страница 4: ...Contents R S RTB2000 4 Getting Started 1333 1605 02 08 4 1 Front panel 25 4 1 1 Input connectors 26 4 1 2 Other connectors on the front panel 27 4 2 Rear panel 27 5 Contacting customer support 29 ...
Страница 5: ...ou of potential dangers and gives instructions on how to prevent personal injury or damage caused by dangerous situations Safety information is provided as follows In Chapter 1 1 Safety instructions on page 5 The same information is provided in many languages as printed Safety Instructions The printed Safety Instructions are delivered with the product Throughout the documentation safety instructio...
Страница 6: ... self Use the instrument handles to move or carry the instrument Do not use the mounted accessories instead of the handles Accessories are not designed to carry the weight of the instrument To move the instrument safely you can use lifting or transporting equipment such as lift trucks and forklifts Follow the instructions provided by the equipment man ufacturer Choosing the operating site Only use...
Страница 7: ...nnecting to power and grounding The mains power supply input of the instrument complies with overvoltage cate gory II It has to be connected to a fixed installation used to supply energy con suming equipment such as household appliances and similar loads Be aware that electrically powered products have risks such as electric shock fire per sonal injury or even death Take the following measures for...
Страница 8: ...xceed the value specified in the data sheet Observe all voltage and current ratings of the instrument the probes and the accessories Limits and ratings are marked on the products and listed in the data sheets Consider that the rated voltage depends on the frequency The voltage limita tion curves or values are provided in the data sheet Do not exceed the maxi mum measurement voltage from the probe ...
Страница 9: ...ctive measures to pre clude direct contact with the measurement setup Do not touch exposed connections and components when power is applied Switch off the test circuit while connecting and disconnecting probe leads Use only insulated voltage probes test leads and adapters Make sure that the input leads fulfill the safety requirements for your measure ment The delivered input leads might have a jac...
Страница 10: ...ithout rated measurement category For measurements performed on circuits not directly connected to mains for example electronics circuits powered by batteries and specially protected secondary circuits This measurement category is also known as CAT I CAT II For measurements performed on circuits directly connected to the low voltage installation by a standard socket outlet for example household ap...
Страница 11: ...onductor terminal Connect this terminal to a grounded external conductor or to protective ground This protects you against electric shock should an electric problem occur 1 2 Labels on the product Labels on the casing inform about Personal safety see Meaning of safety labels on page 11 Product and environment safety see Table 1 1 Identification of the product Table 1 1 Labels regarding product and...
Страница 12: ...verity of the safety hazard and how likely it will occur if you do not follow the safety precautions WARNING Potentially hazardous situation Could result in death or serious injury if not avoi ded CAUTION Potentially hazardous situation Could result in minor or moderate injury if not avoided NOTICE Potential risks of damage Could result in damage to the supported product or to other property Warni...
Страница 13: ...Safety and regulatory information R S RTB2000 13 Getting Started 1333 1605 02 08 1 4 CE declaration of conformity CE declaration of conformity ...
Страница 14: ...Safety and regulatory information R S RTB2000 14 Getting Started 1333 1605 02 08 1 5 UKCA declaration of conformity UKCA declaration of conformity ...
Страница 15: ...d regulatory information R S RTB2000 15 Getting Started 1333 1605 02 08 1 6 Korea certification class A 이 기기는 업무용 A급 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하 시기 바라며 가정외의 지역에서 사용하는 것을 목적으로 합니다 Korea certification class A ...
Страница 16: ...es an introduction to remote control a complete description of the remote control commands with programming examples and information on maintenance and instrument interfaces Includes the contents of the getting started manual The online version of the user manual provides the complete contents for immedi ate display on the internet Instrument help The help offers quick context sensitive access to ...
Страница 17: ...ies The brochure provides an overview of the instrument and deals with the specific characteristics See www rohde schwarz com brochure datasheet rtb2000 2 3 Calibration certificate The document is available on https gloris rohde schwarz com calcert You need the device ID of your instrument which you can find on a label on the rear panel 2 4 Release notes and open source acknowledg ment The release...
Страница 18: ...king material Use it when transporting or shipping the product later 3 Using the delivery notes check the equipment for completeness 4 Check the equipment for damage If the delivery is incomplete or equipment is damaged contact Rohde Schwarz Delivery contents The delivery package contains the following items R S RTB2000 oscilloscope R S RT ZP03 probes 2x for R S RTB2002 4x for R S RTB2004 Country ...
Страница 19: ... that are directly connected to a low voltage supply network that supplies residential buildings Class A equipment is intended for use in industrial environments It can cause radio disturbances in residential environments due to possible conducted and radiated disturbances It is therefore not suitable for class B environments If class A equipment causes radio disturbances take appropriate measures...
Страница 20: ...duct on top of the product As an alternative you can mount several products in a rack 4 NOTICE Overheating can damage the product Prevent overheating as follows Keep a minimum distance of 10 cm between the fan openings of the prod uct and any object in the vicinity Do not place the product next to heat generating equipment such as radia tors or other products 3 4 2 Mounting the product in a rack T...
Страница 21: ...ack brackets with a tightening torque of 1 2 Nm to secure the product at the rack To unmount the product from a rack 1 Loosen the screws at the rack brackets 2 Remove the product from the rack 3 If placing the product on a bench top again unmount the adapter kit from the product Follow the instructions provided with the adapter kit 3 5 Considerations for test setup Observe safety instructions see ...
Страница 22: ... device under test DUT Ground yourself to prevent electrostatic discharge damage a Use a wrist strap and cord to connect yourself to ground b Use a conductive floor mat and heel strap combination During operation if the firmware observes a serious unexpected disturbance e g due to ESD it resets some hardware components and initiates a new alignment to ensure proper instrument functioning Then it r...
Страница 23: ...Standby yellow I on Ready green I on To switch on the product The product is off but connected to power 1 Set the switch on the power supply at the rear panel of the instrument to posi tion I The power key lights up The key is located in the bottom left corner of the front panel 2 Press the Standby key The instrument performs a system check and then starts the firmware The Standby key turns green ...
Страница 24: ... power source 3 8 Changing fuses If the product does not start it is possible that a blown fuse is the cause The product is protected by a fuse of type Size 5x20 mm 250V T2 5H slow blow IEC60127 2 5 1 WARNING The fuse is part of the main power supply Handling the fuse while the power is on can lead to electric shock Before changing the fuse a Set the switch on the power supply to position 0 b Disc...
Страница 25: ...4 1 Front panel of R S RTB2004 with 4 input channels 1 Display 2 Horizontal and vertical setup controls 3 Trigger settings action and analysis controls 4 Analog input channels 2 channels at R S RTB2002 4 channels at R S RTB2004 5 External trigger input 6 Logic probe connectors option R S RTB B1 7 Connectors for probe compensation and optional pattern generator R S RTB B6 8 USB connector 9 Aux Out ...
Страница 26: ...measurements on page 8 Working with hazardous voltages on page 9 The maximum input voltage on channel inputs must not exceed 400 V peak and 300 V RMS For the external trigger input the maximum input voltage is 400 V peak and 300 V RMS Transient overvoltages must not exceed 400 V peak Logic probe 6 The connectors for logic channels can be used if the Mixed Signal Option R S RTB B1 is installed The ...
Страница 27: ... channel Square wave signal for probe compensation Ground connector for probes USB type A 8 USB 2 0 type A interface to connect a mouse or a keyboard or a USB flash drive for storing and reloading instrument settings and measurement data and to update the firmware Aux Out 9 Multi purpose BNC output that can function as pass fail and trigger output output of 10 MHz reference frequency and as wavefo...
Страница 28: ...heft 6 not used LAN 1 8 pin connector RJ 45 used to connect the instrument to a Local Area Network LAN It supports up to 1 Gbit s USB type B 2 USB 2 0 interface of type B device USB for remote control of the instrument AC supply mains connector and main power switch 3 The instrument supports a wide range power supply It automatically adjusts to the correct range for the applied voltage There is no...
Страница 29: ...oduct contact our customer support center A team of highly qualified engineers provides support and works with you to find a solution to your query on any aspect of the operation program ming or applications of Rohde Schwarz products Contact information Contact our customer support center at www rohde schwarz com support or fol low this QR code Figure 5 1 QR code to the Rohde Schwarz support page ...